ISO13485 Medical ETCO2 Sensor Multiscene CAPNOSTAT 5 Compatible

Country/Region china
City & Province dongguan guangdong
Categories Electrical Plugs & Sockets
InquireNow

Product Details

Edan Mainstream etCO2 sensor CAPNOSTAT 5 compatible

 

ETCO2 Sensor Specification
ProjectSpecifications 
Principle of OperationNon-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts.
Initialization TimeCapnogram displayed in less than 3 seconds,full specifications within 3 minutes(At 25°C).
CO2 Measurement Range0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa.
CO2 Rise TimeRise Time Less than 80 ms - Adult Reusable or Single-Patient-Use Airway Adapter Less than 80 ms - Infant Reusable
or   Single-Patient-Use Airway Adapter.
CO2 Resolution0. 1mmHg ;   0 to 38 mmHg.;   0.25 mmHg ;   39 to 114mmHg.
CO2 Accuracy0 - 40mmHg ±2 mmHg.;   41 - 76mmHg ±5% of reading.;   77 - 114 mmHg ±8% of reading.
Above 80 breaths per minute ±12% of reading.     * Note: Gas emperature at 25°C.
CO2 StabilityShort term drift: Drift over four hours shall not exceed 1 mmHg maximum.
Long term drift: Accuracy specification will be maintained over a 120-hour period.
Sampling Frequency100Hz.
Respiration Rate Range3 to 150 breaths per minute.
Respiration Rate Accuracy±1 breath.
CalibrationNo routine user calibration required. An airway adapter zero is required when changing to a different style of airway
adapter.
Airway AdaptersSingle-patient-use or reusable, < 5 cc dead space (adult), < 1 cc dead space infant.
TemperatureOperating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C.
HumidityOperating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing.;
Transport: 10 to 90% RH, non-condensing.
Atmospheric PressureOperating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg.
Water ResistanceIPX4 - Splash-proof - Sensor only.
Voltage Requirements5VDC ± 5 %.
Power Rating<1.0W Typical; <1.8 W Warm-up.
Sensor Weight<85g.
Sensor SizeDeep*Wide*High:48mm * 24.3mm * 35.5mm.
Cable Length2.4m.

 

 

Hot Products

Spo2 adapter cable Compatible with Nellcor DEC-8 Product Description Cable Color Gray Cable Material ...
#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family...
Reusable Adult NIBP cuff blood pressure PU cuff, Single/Double tube with bag, 33-47cm #detail...
Nellcor Compatible MAX-A,MAX-P,MAX-N Disposable Spo2 sensor Portable Nellcor Pediatric Spo2 Sensor, ...
Product Name:11 Pin GE Healthcare to BB Transducer Blood Invasive Pressure IBP OEM Part Number Cross ...
Med Accessories Medical BCI ECG Monitor Cable 6 Pin 5 Leads Multipurpose 0.9m Size OEM Part Number ...