Home Companies Wuhan Spico Machinery & Electronics Co., Ltd.

1500GPM Horizontal Split Case Double Suction Centrifugal Pump With Single Stage

Wuhan Spico Machinery & Electronics Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Rm. E, 16th FL., Century Bldg. No. 206, Jianghan Rd., Hankou, Wuhan, China

Contact name:Kathy Wong

Inquir Now

Wuhan Spico Machinery & Electronics Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

1500GPM Horizontal Split Case Double Suction Centrifugal Pump With Single Stage

Country/Region china
City & Province wuhan hubei
Categories Pumps
InquireNow

Product Details

1500GPM Horizontal Split Case Double Suction Centrifugal Pump With Single Stage
 
 
There are two main types of the split case pump. When the casing is split along a vertical plane with respect to the impeller, it is referred to as a vertical split case pump. When the casing is split along a horizontal plane, it is referred to as a horizontal split case pump. The later type of casing design is more economical in applications that require significantly higher flows, and its impeller can be supported using bearings on two sides, which is an advantage for larger, higher flow pumps.
The split case pump has both the discharge and suction connections in the lower half of the pump casing, in an opposing configuration to each other. The pump’s impeller is normally mounted on a shaft that is supported by bearings on two sides.
 
 
Parameters:
HEADPUMP MODELSPEEDMAX SHAFT POWER
PSIFEETMETERRPMHPKW
11526581SCF200-150-460 (8X6")1800
(60Hz)
231172.1
 

KEY FEATURES
  • Single stage, medium pressure double inlet centrifugal pump with two flanged bearing frame, suitable for flexible coupling to electric motor or internal combustion engine as a driver;
  • Ample dimensioned shaft guided through roller bearings and hardened shaft sleeve;
  • Fully-enclosed single piece casting, double inlet impeller practically doesn’t produce any axial trust;
  • High operating reliability due to maintenance and service parts;
  • Spiral housing axially spitted means easy maintenance without pipe disconnection.

 

 

Performance Ranges:
 

UL:

 

Q: 500-4000GPMH:100-190PSI

 

FM:

 

Q: 500-4000GPMH:100-190PSI

 

CCCF:

 

Q:20-500L/SH:0.42-2.0Mpa

 

NFPA20:

 

Q: 300-8000GPMH:60-300PSI
 
 
 

Application:

 

For liquid transfer and circulation of cold clean or slightly polluted water. Typical applications in:
  • Municipal water supply;
  • Power plants;
  • Industrial plants;
  • Boiler feed and condensate systems;
  • Irrigation and dewatering;
  • General purposes.
 

 

Advantage:

 

First-Class international technical standards

 

Horizontal Split Case (HSC) pumps are given their name due to the “split”” design of the casing, where the casing cover can be lifted off of the pump to expose the internal components. These components include the impeller, bearings, pump shaft, and so on. HSC pumps have two bearings, located on either side of the impeller, which are useful to withstand the large amount of vibration and thrust forces often caused 

by water turbulence in the suction piping. The pump casings are often designed to handle higher working pressures, and are often heavier. The durability of the HSC design allows the pump to be used for very large water flows – often in excess of 5000 GPM. It should be noted that an HSC pump is not always mounted horizontally, it is possible to have the same durability design features and have the pump designed to be mounted vertically.

 

Hot Products

NFPA20 Horizontal Split Case Fire Pump For Schools / Supermarkets 1500gpm@300 Feet A split case pump ...
High Performance Split Case Fire Pump , Fire Fighting Water Pump 180kw Shaft Power Horizontal Split ...
1500GPM Horizontal Split Case Double Suction Centrifugal Pump With Single Stage There are two main ...
NFPA20 Standard UL Listed FM Approved 500GPM @ 312 feet Horizontal Split Case Fire Pump There are ...
UL/FM 500GPM @ 300feet Horizontal Split Case Fire Pump NFPA20 Standard There are two main types of ...
UL Listed / FM Approved 500GPM @ 120 PSI Horizontal Split Case Fire Fighting Pump The orientation of ...