Home Companies Ningbo Nijia Electronics Technology Co.,Ltd

AD -5 Orion Stainless Steel Auto Drain Valve Instead Of PA -68 For Refrigeration Facilities

Ningbo Nijia Electronics Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: ZHONGXING EAST ROAD 208, XIKOU TOWN315502, FENGHUA CITY, ZHEJIANG PROVINCE, CHINA

Contact name:Ricky

Inquir Now

Ningbo Nijia Electronics Technology Co.,Ltd

AD -5 Orion Stainless Steel Auto Drain Valve Instead Of PA -68 For Refrigeration Facilities

Country/Region china
City & Province zhejiang
Categories Valves
InquireNow

Product Details

 

AD -5 Orion Stainless Steel Auto Drain Valve Instead Of PA -68 For Refrigeration Facilities

Description

 

Operating Manual
Orion High reliability Automatic drain valve AD-5
Refrigeration facilities

1. Note: The product is for industrial. Please attention to use.
2. For the proper operation of the product, please readthis carefully.

For security, be sure to comply with it.
Warning: if use it in a wrong way, may cause the user serious injury or death.
1. When clean, repair and check, please pumping out the compressed air in the pressure container. If there is residual air, the component will fly up, cause damage.
2. For installation, must according to this manual. Wrong installation will cause water leakage or air leakage.
3. Do not use other liquid, only the specified. Authorized liquid, is compressed air, Others may cause the product broken, like breakdown, leakage and etc.
4. Confirm the piping of drainage. Inappropriate piping, will cause leakage and get wet the facility.
5. When transfer and lend the products, please transmit the manual too. When sell or transfer the used products, in order to let the new user could use safely, please place the manual obviously.
6. No drain without water. Please close the handle of the inlet drainage device. Or, the valve core will be abnormal abrasion.
7. How to keep the product (Long time without use)
1). Dismantle the product after close the ball valve.
2). Drain out the water in drain-pipe. Get rid of the water in the drainage device. Observe from the bottom up, turn right, to drain out the water in the cup.
3). Keep away the garbage, dust and rainwater when keep the product.
Attention: If there's water residual in the drain-pipe, will cause the internal parts corrosion and damage, lead to breakdown.

Installation
1. Attention: As include plastic parts, cannot be installed at the environment which contains the following materials. Direct sunlight also should be avoid.

Chemicals TypeTypeMain productsGeneral use
Inorganic chemicalsAcidHydrochloric acid, Sulfuric acid, Fluorine acid, Phosphoric acid, Chromic acid, etcMetal pickling solution, Acidic degreaser, Leather coating liquid
Orgnic chemicalsAromatic hydrocarbonBenzene, Toluene, Xylene, Ethylbenzene, Styrene, etcPaint diluent
AlcoholMethyl alcohol, Medicinal alcohol, Cyclohexylethanol, Benzil alcohol, etcAntifreeze liquid
PhenolMethyl carbonate, Cresol, Naphthol, etcRaw material of Detergent and Phenol resin
KetoneAcetone, Methyl ethyl ketone, Cyclohexanone, Acetopheneone acid, etc 
Carbon acidFormic acid, Acetic acid, Butyric acid, Acrylic acid, Oxalic acid, Phthalate, etcChemical base of Dyeing agent and Aluminum coating treatment
Oxygen acid; AlkydGlycolic acid, Lactic acid,
Malic acid, Citric acid, etc
Food additive
AmineMethylamine, Dimethylamine,
Ethylamine, Aniline, Acetainilide, etc
Brake oil additives, Antistatic agent, Dye for plastic

2. Installation method.
Note: When install the drain-pipe, please be sure the status in outlet. Inappropriate piping, will cause leakage and get wet the facklity.
1). Pipe size
Inlet: Rc1/2    Outlet: Rc1/2
2). Installation and piping of drainage
When the drain-pipe outlet is downward, the product should be vertical installation. Check valve must be installed at the drain-pipe inlet.

Application method
1. Regulate the water displacement
The working clearance of drainage device will be different, according to the load and pressure. Cannot regulate the valve when the cup filed with water.
2. Note: Water comes from the compressed air is limited, so please do not set for empty working continuous. If not, will cause:
1). Valve core will be abnormal abrasion.
2). The insterstice will get shorter.
3). Abrasion will be speed up.
4). Spray continuously.
3. Note: If there is too much oil, will cause:
1). Output will be reduced.
2). The interstice will get longer. If there is too much oil, please regulate the oil regulator.

Quality Standards
The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount. But the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance. According to the original quality standards, during warranty with product problems, need confirmation testing by the manufacturer, the supplier to be solved, the demand side due to storage, use, poor maintenance caused by lower-quality product, and not raise

objections.

Competitive advantage

Our product featuresOur Services Guarantee:
1) Competitive price1) Prompt respond (Reply with 24 hours)
2) Good quality2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging3) Registration support.
4) Produce according to Customers’ instruction4) Photos/videos are available during production.
5) None delay shipment5) Loading inspection, and send loading photos before shipment.

In addition

The product include the diaphragm big/small and spring. If you have received the product has a problem, please let me know, I will help you to solve the question first time.

Delivery

The products will be sent out together by TNT, Fedex, DHL, or SF Express and so on. Of cause, if you have a special requirements, we will do as you told.

Pictures show

Hot Products

AD -5 Orion Stainless Steel Auto Drain Valve Instead Of PA -68 For Refrigeration Facilities ...
PA -68 Anti Bloking Compressor Automatic Drain Valve Gas Tank Filter ZDPS -15 Description Features 1...
DIN43650 Hydraulic Solenoid Coil Tube Φ13 High 37.7mm 20.5W Electric Circuits DC12V DC24V Descriptio...
HYVA Dump Truck Valve 14750430H double acting proportional air control air control tipping valve The ...
14750152H 3 Position Pneumatic Distributor Valve Pressure Air Contorl Valve Tipper Air Control ...
HYVA 14750650H Dump Truck Valve Controls Air Control LED 2 Sections Fix Tipping Position Description...