UK type plug socket tester pro with RCD GFCI Voltage Measurement and LED indication

 

 

Product warranty instructions

 

Product certification is your instrument in the use of failure, seeking repair services must have, and then you purchase the invoice at the same time to be effective.

1) When your multimeter in use fails, please contact our maintenance department as soon as possible, consultation, so as not to delay your use and warranty period.

2) The product of the Company from the date of purchase from the warranty service. In the event of failure during the warranty period, the company professionals to confirm the reasons for the failure of non-users, the company free warranty service.

3) If the warranty period is exceeded, the cost will be charged (repair fee + component fee).

4) Even during the warranty period, maintenance fees are charged in the following cases.

⑴ due to improper use of the user or accidental disaster events and damage to the components and burn the circuit board.

⑵ non-professional staff of the company open shell, inspection, modification.

⑶ failure to comply with the instructions specified in the operation.

⑷ not the company's products do not maintain repair.

⑸ due to maintenance caused by postage, transportation and other users themselves.

⑹ multimeter battery, table pen, temperature probe and other functional accessories and supplies are not free warranty list.

 
 
Technical indicators
 
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
 
 
 
3.2.2 DC voltage

RangeResolutionAccuracy
6V0.001V±(0.5% of reading + 5 words)
60V0.01V
600V0.1V±(0.8% of reading + 5 words)

- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
3.2.3 AC voltage
 

RangeResolutionAccuracy
6V0.001V±(0.8% of reading + 3words)
60V0.01V
600V0.1V±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
 
3.2.4 Alternating current
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.5% of reading +10words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.5% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
 
3.2.5 DC
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.0% of reading +5words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.0% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 
 
3.2.6 Frequency
 

RangeResolutionAccuracy
9.999Hz0.001Hz±(1.0% of reading +3words)
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz0.001kHz
99.99KHZ0.01kHZ
999.9KHZ0.1KHZ
9.999MHZ0.001MHZ

- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
 
 
3.2.7 Duty cycle
 

RangeResolutionAccuracy
0.1 – 99.9%0.1%± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)
 
 

Resistance
 

RangeResolutionAccuracy
600W0.1W±(0.8% of reading +3words)
6kW0.001kW
60kW0.01kW
600kW0.1kW
6MW0.001MW±(1.2% of reading +3words)
60MW0.01MW

- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
 
 

Transistor test

 

RangeDescriptionTest Conditions
hFEThe display reads the approximate value of hFE(0~1000)Base current of about 10uA; Vce about 2.8V

 

 

Capacitance

 

RangeResolutionAccuracy
9.999nF0.001nF±(4.0% of reading +3words)
99.99nF0.01nF
999.9nF0.1nF
9.999mF0.001mF
99.99mF0.01mF
999.9mF0.1mF
9.999mF0.001mF±(5.0% of reading +3words)
99.99mF0.01mFNot calibrated

- Overload protection: 250V DC or AC (rms)

 

 

Temperature test

 

RangeAccuracyResolution
-20℃-300℃±(1.0%+4d)1℃
301℃-1000℃±(1.9%+5d)1℃
-4℉-600℉±(1.2%+6d)1℉
601℉-1832℉±(1.9%+6d)1℉

- Overload protection: 250V DC or AC (rms)

 

 

Hot Products

2000 counts Digital Lux Meter 9.999nF/99.99nF/999.9nF General Description This Light Meter is ...
110V 220V Socket Tester Outlet Tester for Home renovation socket check Measure current 1) Turn the ...
EN EURO USA CHINA model GFCI circuit RCD Voltage Smart Socket plug tester Non - contact voltage ...
UK type plug socket tester pro with RCD GFCI Voltage Measurement and LED indication Product warranty ...
USA Electrical Socket Circuit Receptacle Outlet Tester Preparation 1.1.1 When using the instrument, ...
Overload protection Digital Lux Meter 200KΩ/2MΩ/20MΩ/200MΩ Description: 1. Overload protection 2. ...