Home Companies SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

50Hz 60Hz RMS Digital Multimeter Relative measurement Clamp On Multimeter

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
Active Member

Contact Us

[China] country

Address: 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China

Contact name:Emily Tan

Inquir Now

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

50Hz 60Hz RMS Digital Multimeter Relative measurement Clamp On Multimeter

Country/Region china
City & Province shenzhen guangdong
Categories Electric Wrenches
InquireNow

Product Details

50Hz ~60Hz Digital Clamp Multimeter Relative measurement

 

 

Maintenance
1.4.1 Please do not attempt to test lead the shell to adjust or repair instrument, this operation can only be fully understood by technicians
1.4.2 Before test leading the instrument bottom shell and the battery cover, should be removed the test lead from the measured line test lead
1.4.3 In order to avoid false readings may cause electric shock, when the instrument display “” symbol,
The battery should be replaced immediately.
1.4.4 Use a damp cloth and a mild detergent to clean the instrument; do not use abrasive detergents or solvents.
1.4.5 The instrument when not in use should turn off the power,
1.4.6 If you do not use a meter long time, the battery should be removed to prevent damage to the instrument.
 
 
Description
- The instrument is an professional measuring instrument with liquid crystal display and a back light source. The user readings in easily. Single hand operation with overload protection and low battery indicator. For professional, factory, school, lovers or family use, is an ideal Multi-function instrument.
- Used for AC DC voltage,AC current, frequency, resistance, capacitance measurement and the on-off circuit, measurement, temperature measurement .
- Automatic range
- Data keep
- Auto power off
- Relative measurement
 
 
Technical indicators
Environment temperature:23±5℃ Relative humidity:<75%
 
 
3.2.1 AC Current

RangeResolutionAccuracy
6A0.001A±(3.0% + 20)
60A0.01A±(2.5% + 8)
600A0.1A±(2.5% + 10)

-Min input current:0.01A AC
- Max input:600AC
- Frequency:50Hz ~60Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
 
 
3.2.2 DC voltage

RangeResolutionAccuracy
6V0.001V±(0.5% + 3)
60V0.01V
500V0.1V±(0.8% + 5)

- Min/ input voltage:0.9V DC
- Input impedance:10MW
-Maximum/ input voltage:500V AC (Effective value)OR 500V DC
 
3.2.4 AC voltage 

RangeResolutionAccuracy
6V0.001V

 

±(1.0% + 5)

60V0.01V
450V0.1V±(1.2% + 5)

- Min/ input voltage:0.9V DC

-Input impedance:10MW

- Maximum/ input voltage:450V AC (Effective value)or 450V DC

- Frequency range:45Hz ~100Hz
 
 
3.2.5 Frequency 

RangeResolutionAccuracy
99.99Hz0.01Hz

±(0.1% + 2)

 

 

 

±(0.1% + 2)

 

999.9Hz0.1Hz
9.999kHz0.001kHz
99.99KHZ0.01kHZ
999.9KHZ0.1kHZ
9.999MHZ0.001MHZ

- Overload protection:250V DC or AC(Effective value)
- Input range:≥ 200mV~10VPP(Effective value)With the increase of the measured frequency, the input voltage should be increased)

 
3.2.6 Resistance

RangeResolutionAccuracy
6kW0.001kW±(0.8% + 3)
60kW0.01kW
600kW0.1kW
6MW0.001MW±(1.2% + 3)
10MW0.1MW

- Overload protection:250V DC or AC(Effective value)
 
 
3.2.7 Continuity test

RangeResolutionFunction
 0. 1WIf the measured line resistance is less than 50, enclosing the instrument may sound a buzzer

- Overload protection:600V DC or AC(Effective value)
 
 
3.2.8 Temperature test

RangeAccuracyResolution
-20℃-300℃±(1.0%+4d)1℃
301℃-1000℃±(1.9%+5d)1℃
-4℉-600℉±(1.2%+6d)1℉
601℉-1832℉±(1.9%+6d)1℉

- Overload protection: 250V DC or AC (rms)
 
 
3.2.9 Capacitance

RangeResolutionAccuracy
9.999nF0.001nF±(4.0% of reading +20words)
99.99nF0.01nF±(2.0% of reading +5words)
999.9nF0.1nF
9.999mF0.001mF±(2.0% of reading +5words)
99.99mF0.01mF
999.9mF0.1mF
9.999mF0.001mF±(5.0% of reading +3words)
99.99mF0.01mFNot calibrated

- Overload protection: 250V DC or AC (rms)
 
 
 

Hot Products

Digital Non-Invasive Inductive LED 4-in-1 Tester Wood Drywall Masonry Moisture Meter Description - ...
0.02A AC - 400A AC Digital Clamp Multimeter For Temperature Measurement Safety Instructions This ...
Automatic Power Off Infrared Themometer Digital Clamp Multimeter function exchange Press Power ...
Auto Ranging / Manual Ranging Digital Clamp Multimeter 1.5V AAA Battery GENERAL SPEClIFICATIONS Auto...
50Hz ~60Hz Digital Clamp Multimeter Relative measurement Maintenance 1.4.1 Please do not attempt to ...
10MW Data keep Digital Clamp Multimeter for AC DC voltage Maintenance 1.4.1 Please do not attempt to ...