EN 16825 Refrigerated Storage Cabinets Door Open Close Test System

 

Product overview

The refrigerated storage cabinets door drawer open and close test equipment is designed and manufactured according to EN 16825:2016 standard and customer customized requirements, it is used for the durability test of the vertical door of the vertical refrigerated storage cabinets, and also used for the door opening and closing actions in conjunction with the energy consumption test. It is a dedicated fully automated test equipment, suitable for testing and certification agencies, factory laboratories and other testing departments.

This equipment adopts PLC intelligent control and standard color LCD touch screen, it is equipped with position adjustable actuators and vacuum suction cups to absorb the surface of door. The test angle, speed, and door opening and closing time can be preset, so as to truly simulate the opening and closing actions, achieving an intelligent control method and multiple functions in one machine.

 

Technical parameters

No:ItemContents
1Input power supplyMatch client's local power supply requirements
2Electrical controlMitsubishi PLC
3OpertationWeinview 7” touch screen
4DriveCylinder
5Suitable samples

Max. 2 vertical sections, and each vertical section has 1 door

(Or can be customized)

6Column

Left column of door opening and closing, right column of door opening and closing, each column contains a lifting mechanism, which can adjust the height of the manipulator to match the door opening and closing position

(Or can be customized according to specimen types and quantities)

7Manipulator

Left manipulators for door opening and closing :1 set (arranged on the column of door opening and closing);

Right manipulators for door opening and closing :1 set (arranged on the column of door opening and closing);

(Or can be customized according to specimen types and quantities)

8Adsorption structure

Vacuum suction cup, continuous and stable adsorption, will not fall off, each set of manipulator is equipped with one set

(Or can be customized according to specimen types and quantities)

9Door opening and closing timesCan be preset on touch screen, 0-999999 adjustable, automatically stop testing after the preset test times are reached
10Door opening and closing angle0-90°can be preset on the touch screen , can be adjustable
11Door opening and closing angle dwell timeCan be preset on the touch screen,0-99999.9S can be adjustable
12Door opening and closing speed0-10 times/min, can be preset on the touch screen , can be adjustable
13Door opening and closing interval timeCan be preset on the touch screen, 0-99H59M59S can be adjustable
14Door opening and closing total test timeCan be preset on the touch screen, 0-99H59M59S can be adjustable
15Auxiliary positioning mechanism for samplesOne set, fixed the distance between the refrigerated storage cabinet and the test equipment
16Test contentsDoor opening and closing
17ProtectionSafety protection such as leakage, short circuit and overload
18Equipment overall dimensionsWDH=approx. 1300×900×2000mm
19Equipment weight180kg
 

Working principle and equipment structure

Working principle

The opening and closing of the door adopts a double-cylinder structure, the opening action is completed by one cylinder, and the closing action is completed by another cylinder. The opening cylinder is softly connected to the vacuum suction cup, and the closing mechanism has an angle limit function.

 

Equipment Structure

It adopts column structure, it is equipped with a two-station door opening and closing column structure. Each column contains one set of door opening and closing mechanisms, which can meet the test of a refrigerated storage cabinet with one vertical door in two vertical directions. The structure can be customized according to client's specimen's types and quantities.

 

 

Hot Products

IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151 System introduction: This air enthalpy ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...