Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60335-2-17 Electrical Blanket Spark Ignition Testing Equipment

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60335-2-17 Electrical Blanket Spark Ignition Testing Equipment

Country/Region china
City & Province guangzhou guangdong
Categories Other Roadway Products
InquireNow

Product Details

 

IEC 60335-2-17 Blanket Spark Ignition Test Apparatus

 

Product overview:

 

This device meets the standard of IEC 60335-2-17, Clause 30.101 Figure 113 & 113a.

It is used to inspect the flexible electrical heating appliance flammability, to test whether the charged body arcing caused overheating or combustion.

In a 65 ± 2 ° C in a heating cabinet, supply the sinusoidal rated output voltage 10KV, pass through the position where is 6±0.1mm far from the two Φ3mm copper electrodes phase, then record the time when ignition flame of the sample between the electrode reaches to the inner edge of the template time, ignore if combustion ≤ 3s, record 120s if non-combustion.

 

Technical Parameters:

 

1. The spark ignition test device consists of a control box (including 10KV power), heating chamber (optional) and bracket.

2. The test bracket is shown as figure 113 & 113a of IEC 60335-2-17, the structure is made of stainless steel, insulation material and brass.

 

Specifications for Test Bracket
Adjustable platform

100X100mm, adjustable stroke 0-100mm, made of heat insulation material

Under TemplatesManufactured according to standards, hardwood
Fixed electrodeφ3mm, top inverted cone angle 45 °, made of brass
Upper template

Manufactured according to standard production, hardwood or aluminum

TerminalsMade of Copper
Moving electrodeφ3mm, cylinder, flat top, made of brass, adjustable distance between the electrodes 6 ± 0.1mm
BaseMade of thermal insulation material
 

3. Control Chamber:

   A. Output Power: Voltage 0 ~ 15KV, current 0 ~ 2mA; when the short-circuit current is 1mA, the voltage drop is less than 100V

   B. Power on test time: 0 to 9999s, can be preset

   C. Record time from power on to the flame reaches the inner edge of the template: 0 to 9999 s

4. Natural ventilation heating chamber (optional):

   A. Heating temperature: 0-200 °C can be preset, fluctuation ±1 °C

   B. heating time 0 to 99 hours 59 minutes 59 seconds, can be preset

   C. Inner size L*W*H = 450X450X500mm

 

 

 

 

 


 

Hot Products

IEC 60312 Vacuum Cleaners Comprehensive Performance Test System System Overview: The system is ...
ISO 15502 Refrigerator Freezer Energy Efficiency Performance Test Chamber Overview: This refrigerato...
60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151 System introduction: This air enthalpy ...
30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter System overview This air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...