Home Companies Sinuo Testing Equipment Co. , Limited

Medical Mask Tester Ethylene Oxide Residual Amounts Detector Programmable Gas Chromatograph 225L

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Medical Mask Tester Ethylene Oxide Residual Amounts Detector Programmable Gas Chromatograph 225L

Country/Region china
City & Province guangzhou guangdong
Categories Rubber Product Making Machinery Parts
InquireNow

Product Details

 

Medical Mask Ethylene Oxide Residual Amounts Detector Programmable Gas Chromatograph

 

Product overview:

 

The medical mask ethylene oxide detector adopts a 7-inch color touch screen, and the gas circuit adopts EPC (electronic pressure closed-loop control), EFC (electronic flow closed-loop control) technology, which can be adjusted arbitrarily within the setting range; one button starts automatically. It has functions of automatic heating, ignition, self-check, air leakage alarm, and can store and call various sample conditions; computer back control and host touch screen realize synchronous two-way control; with 8 external events extended function interface, optional Various control valves; the external link method is network port connection (RJ45).

 

The medical mask ethylene oxide detector is suitable for all disposable medical supplies that are sterilized by ethylene oxide sterilization equipment for the detection of ethylene oxide residual gas spectrometer. Such as disposable medical protective masks, disposable sterile syringes, disposable blood circuit products, disposable blood containers, disposable protective clothing, soft tissue expanders, medical surgical masks, medical absorbent cotton, implantable drug delivery devices, Medical infusion set, medical blood transfusion set, etc.

 

Technical advantages:

 

1. Flexible sampling system. In addition to the universal sampling interface, the machine is equipped with interface protocol docking, which is convenient for the installation of automatic sample injectors and valve center cutting.

2. Adopts high-precision digital precision valve steady flow gas path, two-stage voltage stabilization and steady flow method carrier gas, and high-precision digital precision diaphragm control valve.

3. Perfect gas pipeline and vacuum welding technology. The gas pipelines used in the instrument are made of no-clean high-brightness stainless steel pipelines, which truly provide a dry and clean carrier for high-purity gas.

4. It has functions of low-pressure carrier gas circuit and gas cut protection.

5. The instrument has a high-temperature protection function. If any temperature control exceeds a certain range of the set temperature, the instrument will shut down and stop the operation and give an alarm.

6. The corresponding signal has a wide range and the solvent peak is not flat. It meets the test of high concentration and low concentration. It has good consistency and can meet the needs of high-purity sample analysis.

7. Unique operation control system software and hardware design, the instrument automatically implements the entire software monitoring of the system during the operation process, and fundamentally eliminates the phenomenon of instrument temperature and operating parameters out of control. Achieve "no-fault" over-temperature protection, unique active temperature protection function and dual hardware self-locking over-temperature control structure to ensure the safe operation of the instrument when unattended.

8. The signal output of the instrument can be easily connected with peripheral data processing equipment or drawing equipment such as various chromatographic data processors and chromatographic workstations.

9. Its standard configuration dedicated chromatographic network back-control version workstation can set all numerical parameters of the instrument, control operation, realize two-way communication and two-way protection. The names and types of residual solvents (ug / g) of the residual solvents in the analysis object can be directly detected and output according to the standard sample, which is convenient for the test personnel to refer to the test labels for data analysis.

 

Technical parameters:

 

Column thermostatInner volume225L
Temperature control rangeRT+5℃~400℃
Temperature control accuracy±0.1℃
Heating rate0.1℃~60℃/min
Order of Program heating16
Repeatability of program heating≤2%
Cooling methodBack door
Cooling rateRequired time from 250℃~50℃ is ≤10min
SamplerTemperature control rangeRT+7℃~420℃
Temperature control methodIndependent temperature control
Carrier gas flow control methodConstant pressure
Number of simultaneous installationsUp to 3
Sampling unit typePacked column, split
Split ratioSplit ratio display
Column head pressure range0~400kpa
Column head pressure control accuracy0.1kpa
Flow setting rangeH20~200ml/min N20~150ml/min
DetectorChoose one between FID, TCD
Temperature rangeRT+7℃~420℃
Number of simultaneous installationsUp to 2
Ignition functionAutomatic

Hydrogen flame ionization detector

(FID)

Detection limit≤3*10-12g/s (N-hexadecane)
Baseline noise≤5*10-14A
Baseline drift≤6*10-13A
Dynamic Range107
RSD≤3%
Thermal Conductivity Detector (TCD)Sensitivity5000V.ml/mg (N-hexadecane)
Baseline noise≤0.05mV
Baseline drift≤0.15mV/30min
Dynamic Range105
Power supplyAC 220V/50Hz, or match client’s local power supply requirements
Power3000W
 

Hot Products

IEC 60436 Dishwasher Performance Test System Energy Efficiency Testing Chamber System overview: This ...
IEC 60312-1 European Standard Alternative B Vacuum Cleaner Performance Test Bench System overview: ...
Comprehensive Energy Efficiency Test System for Washing Machines Refigerators Freezers Water Heaters ...
IEC 60312 Vacuum Cleaners Comprehensive Performance Test System System Overview: The system is ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...