Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers

Country/Region china
City & Province guangzhou guangdong
Categories Water Treatment
InquireNow

Product Details

 

Water Efficiency Grades Test System for Reverse Osmosis Drinking Water Treatment Purifiers

 

Overview:

 

Water efficiency grades test system for reserve osmosis drinking water treatment purifiers is designed and manufactured according to GB34914-2017, QBT 4144 and etc. Under the conditions of the test water is well prepared, the water temperature and pressure are well set, the test system measures the total water inlet capacity, total water production capacity, total concentrated water capacity, purified water flow rate and purified water production rate of the drinking water treatment purifiers, to obtain the water efficiency grades of the drinking water treatment purifiers.

 

Standards:

 

Can be designed according to the following standards:

► GB34914-2017

► QBT 4144

► Other international standards

 

Types of UUT :

 

Reverse Osmosis Drinking Water Treatment Purifiers

 

 

Technical Contents:

 

Total water inlet

Total water production capacity

Total concentrated water

Purified water flow rate

Purified water production rate

 

Technical Parameters:

 

No.:NameSpecification
1Test station2 or customized
2Test medium

The following water quality indicators were configured with pure water (conductivity <10 μS/cm, total dissolved solids <5 mg/L) as follows:

a. total hardness should be controlled at (250 ± 20) mg / L;

b. alkalinity should be controlled at (160 ± 20) mg / L;

c. total dissolved solids should be controlled at (500 ± 50) mg / L;

d. pH should be controlled at 7-7.5

3Inlet water temperature25±1℃
4Inlet water pressure0.24±0.02Mpa
5Water flow0~100L/H

Hot Products

Energy Efficiency Testing System with 2 Test Benches 6 Black Corners for Electric Rice Cookers ...
Water Efficiency Grades Test System for Reverse Osmosis Drinking Water Treatment Purifiers Overview: ...
EU ErP Energy Efficiency Dust Removal Performance Testing System for Dry Vacuum Cleaners Overview: ...
10 ~ 3000m³/h 0 ~ 1200Pa Air Volume Measurement System for A.C. Electric Ventilating Fans Overview: ...
Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab of ENERGY STAR Qualified Ceiling Fans Overview: ...
Energy Efficiency Testing Laboratory for Electric Water Storage Heaters 4 / 8/ 10 Stations Overview: ...