Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60068-2-30 -70℃ Temperature And Humidity Test Chamber SN881-1500L

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60068-2-30 -70℃ Temperature And Humidity Test Chamber SN881-1500L

Country/Region china
City & Province guangzhou guangdong
Categories Physical Measuring Instruments
InquireNow

Product Details

 

IEC 60068-2-30 -70℃ Temperature And Humidity Test Chamber SN881-1500L

 

Product overview:

 

It conforms to standards:

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

 

This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the products reliability of storage and transportation under high and low temperature alternating heat and humidity, an necessary test equipment which is required by many standards such as IEC60335-1 clause 15, etc.

 

 

Technical parameters:

 
  1. Sample limitation
This test chamber prohibits:
Testing or storage of flammable, explosive, and volatile substance samples
Testing or storage of samples of corrosive substances
Testing or storage of biological samples
Testing or storage of strong electromagnetic emission source samples
Testing or storage of radioactive material samples
Test or storage of highly toxic substance samples
Testing or storage of samples that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive materials during testing or storage
  1. Volume, size and weight
  1. Nominal content volume
1500L
  1. Inner chamber size
W1000mm×D1500mm×H1000mm
  1. External dimensions
Approx. W1500mm×D2020mmxH2150mm
  1. Weight
Approx.680KG
  1. Performance
  1. Temperature range
Temperature range: -70 ℃~+180℃
  1. Humidity range

(20 ~ 98)% RH (refer to temperature and humidity controllable range chart, no active wet and heat load)

Temperature and humidity controllable range chart

  1. Temperature fluctuation
±0.5℃ (The temperature fluctuation is half of the difference between the measured maximum temperature and the minimum temperature at the center point)
  1. Humidity fluctuation
≤2.5%
  1. Temperature deviation
≤±2.0℃ (Temperature uniformity is the arithmetic mean of the difference between the highest and lowest temperature measured in each test)
  1. Humidity deviation
≤±3%
  1. Temperature display resolution
0.01℃
  1. Humidity display resolution
0.1% RH
  1. Heating rate
Average 2~3℃/min (non-linear under no load)
  1. Cooling rate
Average 0.7~1℃/min (non-linear under no load)
  1. Load conditions
None
  • Working noise

 

Sound level≤75dB

(Measured in a soundproof room with an ambient temperature of 25 ° C and low echo; using A weighting, the average value of 8 points is tested; each test point is 1 meter away from the noise source and 1 meter away from the ground)

  1. Structural characteristics
  1. Material

 

 

1. Outer wall material: A3 plate spraying

2.Inner wall material: SUS304# stainless steel plate
3. Chamber body insulation material: 100mm high temperature resistant rigid polyurethane foam

4. Door insulation material: 100mm high temperature resistant rigid polyurethane foam.

  1. Bottom structural strength
The heavy capacity of the track at the bottom of the test chamber: ≤100Kg/m² (load)
  1. Air conditioning channel

① Stainless steel long-axis centrifugal fans: 4 units/90W.

②Fan, heater, evaporator (also dehumidifier), drainage device, pressure balance port, adjustable air guide plate, temperature sensor

  1. Standard configuration of test chamber

①Window 400x600x40mm 3-layer vacuum tempered glass.

②Flat embedded handle,

③Door hinge: SUS #304 imported hinge

④ Energy-saving lamps in the box: LED energy-saving lamps

⑤Lead hole: φ50mm 1 piece

  1. Door

① The single-piece door opens outwards, with the hinge on the left and the handle on the right (when facing the front of the box).

② Equipped with a safety door locking mechanism (the door can be opened in the test room), the door is equipped with electric heat to prevent condensation, and the viewing range of the insulating glass observation window is approximately (W400×H600mm). Electric heating device to prevent condensation on door frame

  1. Control Panel
There is a 7-inch display screen for temperature (humidity) control and display, an operating indicator light, and a lighting button
  1. Machinery room
Refrigeration unit, compressor water tray, pressure relief device, heating device
  1. Power distribution cabinet
Distribution board, cooling fan, main power switch, transformer, intermediate relay, time relay, solid state relay, AC contactor, circuit breaker
  1. Heater

① Fin-type heat pipe-shaped stainless steel electric heater

②Heating control method: SSR (Solid State Relay) contactless equal period pulse width modulation

③Heating power: about 4KW

  1. Refrigeration system
  1. Refrigeration device

①American Emerson low-noise vortex ultra-low temperature refrigeration system (air-cooled heat dissipation method).

② Cooling method: air cooling

  1. Hot and cold exchange device
Two-stage refrigeration system American Emerson low-noise scroll compressor. Adopting ultra-high efficiency SWEP cold coal cold and heat exchange design [made in Sweden (sus#316)], it is more efficient than the traditional internal spiral type.
  1. Heating load adjustment

①Adopt automatic adjustment of cold coal flow device to effectively take away the heating load of the product to be tested and German/Japanese technology.

②Compared with the traditional design, the control stability and reproducibility are higher, and it achieves super efficiency of saving power and saving more energy.

  1. High efficiency components

①The condenser and evaporator adopt AC&R double spoiler type aluminum fin device.

②The throttling devices adopt imported Chiming refrigeration accessories

  1. Expansion system
Capacity controlled refrigeration system (capillary tube)
  1. Evaporative condenser
All copper tube heat exchanger
  1. Refrigerator control method

①The controller of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions.

②Evaporation pressure regulating valve.

③Compressor return air cooling circuit

④The refrigeration system is designed with vibration and noise reduction measures such as shock absorber tubes.

  1. Refrigerant
Honeywell R404a (ozone depletion index is 0)
  1. Electrical control system
  1. Controller
7 inch smart LCD touch programmable controller
  1. Controller specifications

1. 7-inch true color touch screen

2. Two control methods: program/set value

3. Sensor type: two PT100 inputs (electronic sensor input optional)

4. Output mode: voltage pulse (SSR)/control output: 2 channels (temperature/humidity)/2 channels 4-20mA analog output/16 channels relay output (passive)

5. Control signals: 8 channels IS control signals/8 channels T control signals/4 channels AL control signals

6. Alarm signal: 16 DI external obstacle alarms

7. Temperature measurement range: -90.00℃--200.00℃, (optional -90.00℃--300.00℃) error ±0.2℃

8. Humidity measurement range: 1.0%--100%RH, error ±1%RH

9. Communication interface: (RS232 or RS485, the longest communication distance is 1.2km [optical fiber can reach 30km])

10. Interface language type: English

11. Multiple signal combination relay outputs, the signals can be subjected to logical operations (NOT, AND, OR, NOR, XOR), referred to as PLC programming ability;

12. Diversified relay control methods: parameter->relay mode, relay->parameter mode, logic combination mode, composite signal mode

13. Program editing: 120 groups of programs can be programmed, and each group of programs can have a maximum of 100 segments

  1. Controller technical parameters

Accuracy: temperature ±0.1℃+1digit, humidity ±1%R.H+1digit

Resolution: temperature ±0.01℃, humidity ±0.1%R.H.

Temperature slope: 0.1~9.9 can be set.

It has upper and lower limit standby and alarm functions.

Temperature and humidity input signal dry and wet bulb PT100x2.

9 sets of P.I.D control parameter settings, P.I.D automatic calculation.

Dry and wet bulb automatic correction screen

  1. Control method

①Anti-integral saturation PID

②BTC balanced temperature control method + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature test equipment)

③BTHC balanced temperature and humidity control method + DCC intelligent cooling capacity control + DEC intelligent electrical control (temperature and humidity test equipment)

  1. Screen display function

It adopts screen conversation style, no key input is required, and the options can be directly touched on the screen.

Temperature set (SV) and actual (PV) values are directly displayed.

It can display the currently executing program number, segment, remaining time and number of cycles.

Operation accumulated time function.

The temperature program setting value is displayed in a graphic curve, with the function of real-time display of program curve execution.

It has a separate program editing screen, and at least 5 segments of temperature, humidity and time can be input on each page.

The fault prompt screen is displayed.

The screen backlight can be adjusted.

The screen display protection function can be set to timer, TIMER or manual shutdown.

  1. Program capacity and control functions

Usable program groups: maximum 120 PATTEN.

Usable memory capacity: 12000 SEGMENTS in total.

Repeatable execution of commands: each command can be executed up to 3200 times.

The program is created in a conversational style, with functions such as editing, clearing, and inserting.

SEGMENTS time setting 0~99Hour59Min.

Programmable timing control module device x2 set.

It has a power-off program memory, and automatically starts and resumes program execution after power is restored.

With RS-485 or RS-232 communication interface.

Graphical curves can be displayed in real time when the program is executed.

It has the function of automatically adjusting the freezing capacity.

It has scheduled start-up and shutdown functions.

With date and time adjustment function.

Button and screen lock (LOCK) function.

  1. Safety protection device
  1. Refrigeration system
1. Compressor overheating protection
2. Compressor overcurrent protection
3. Compressor high and low pressure protection
  1. Test chamber
1. Adjustable over temperature protection
2. Limit over-temperature protection of air conditioning channels
3. Fan motor overheat protection
  1. Other protection

1.Leakage Protection

2.Heating tube no air drying protection

3.Overload and short circuit protection

4.Power outage protection

5.Low water level protection

  1. Conditions of use
The following conditions are guaranteed by the user
  1. The installation site

1. The ground is level and well ventilated
2.No strong vibration around the equipment
3.No strong electromagnetic field around the equipment
4.No flammable, explosive, corrosive substances and dust around the equipment
5. Appropriate use and maintenance space is left around the equipment, as shown below:

A:≥40cm B:≥150cm C:≥100cm D: ≥60cm E:≥40com

  1. Environmental conditions
1. Temperature: 5 ℃ ~ 35 ℃
2. Relative humidity: ≤85%
3. Air pressure: 86kPa ~ 106kPa
10.3. Power supply conditionsPower supply requirements:
1. One five-core (three-phase four-wire + protective ground wire) cable (about 4 meters long)
2. Voltage range: Three phase AC 380V
3. Allowable frequency fluctuation range: (50 ± 0.5) Hz
4. The protective earth ground resistance is less than 4Ω
5. The user is required to configure the equipment with an circuit breaker (63A) of the corresponding capacity at the installation site, and this switch must be independently used by the device
10.4. Maximum current
Maximum power consumption

Imax≤32A

Pmax≤13KW

10.5. OthersOpening the door of the test chamber during the test will cause temperature and humidity fluctuations in the chamber; if the door is opened multiple times or is left open for a long time or the test sample emits moisture during the test, the refrigeration system heat exchanger may freeze and does not work.
 
 
Main Configuration List:
 
No.:NameBrandRemark
1ControllerSinuo 
2Humidity SensorSealingPT100 A level accuracy
3Temperature SensorSealingPT100 A level accuracy
4Power supplyCustomized24V
5Over temperature protectorCustomizedRT~300℃
6BreakerChintNXB-63
7ContactorChintNXC-09 NXC-18
8Time RelayCKCHACLH3Y
9RelayChintNXJ/4Z
10ButtonZhuangyin 
11SSRMGR40A
12Phase loss protectorChintXJ3-G
14Electric wireZhujiang 
15CompressorEmersonLow noise scroll type 4 HP
16GlassThree layerWith heating function
17Pressure relayFENSHENGPE300E
18Filter drierMade in Danmark083S
19Capillary tubeET0MA 
20One-way valveDanfoss 
21RefrigerantHoneywellR404A Environmentally friendly refrigerant
22The electromagnetic valveHongsen163/8
23EvaporatorKeweili 
24CondenserGM6.5P
25Plate heat exchangerDanfoss6 P
26Expansion valveDanfossNo. 3
27Heating wireCustomized8KW
28MotorYizheng90W
29CabinetCustomized100MM thick polyurethane foam
 
 
Details:

 

 

 

 

 

 

Hot Products

Vertical Impact Test Equipment Tests For Resistance To Impact IEC 60079-0 Figure A.3 Product ...
IEC 60335-2-84 Cushion Internal Wire Bending Testing Machine Household Appliance Test Product ...
UL 496 Metal Shell Lamp Holder Safety Test Appratus LED Lampholder Testing Equipment Product ...
IEC60068 -70℃ Walk-In Temperature And Humidity Environmental Test Chamber 6m³ Equipment Overview: ...
IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber Product ...
IEC 60068-2-30 -70℃ Temperature And Humidity Test Chamber SN881-1500L Product overview: It conforms ...