Home Companies Wisdomlong Technology CO.,LTD

DLC3010 Fihser HART 249W Digital Level Controller 12~30V DC digital level controller

Wisdomlong Technology CO.,LTD

Contact Us

[China] country

Trade Verify

Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China

Contact name:Mayne

Inquir Now

Wisdomlong Technology CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DLC3010 Fihser HART 249W Digital Level Controller 12~30V DC digital level controller

Country/Region china
City & Province shenzhen
Categories Solar Chargers
InquireNow

Product Details

DLC3010 Fihser HART 249W Digital Level Controller 12~30V DC digital level controller

 

 

Specifications
Specifications for the DLC3010 digital level controller are shown in table 1-1. Specifications for the 249 sensor are shown in table 1-3. Specifications for the Field Communicator can be found in the Product
Manual for the Field Communicator.
Related Documents
Other documents containing information related to the
DLC3010 digital level controller and 249 sensors
include:
Bulletin 11.2:DLC3010 − FIELDVUE DLC3010
Digital Level Controller (D102727X012)
FIELDVUE DLC3010 Digital Level Controller
Quick Start Guide (D103214X012)
Using FIELDVUE Instruments with the Smart
HART Loop Interface and Monitor (HIM) −
Supplement to HART Communicating FIELDVUE
Instrument Instruction Manuals (D103263X012)
Audio Monitor for HART Communications −
Supplement to HART Communicating FIELDVUE
Instrument Instruction Manuals (D103265X012)
Caged 249 Displacer Sensors Instruction Manual
(D200099X012)
Cageless 249 Displacer Sensors Instruction
Manual (D200100X012)
Fisher 249VS Cageless Displacer Sensor
Instruction Manual (D103288X012)
249W Cageless Wafer Style Level Sensor
Instruction Manual (D102803X012)
Simulation of Process Conditions for Calibration
of Fisher Level Controllers and Transmitters —
Supplement to 249 Sensor Instruction Manuals
(D103066X012)
Supplement to 249 Sensor Instruction
Manuals—Bolt Torque Information (D103220X012)
Technical Monograph 7: The Dynamics of Level
and Pressure Control
Technical Monograph 18: Level-Trol Density
Transmitter
Technical Monograph 26: Guidelines for
Selection of Liquid Level Control Equipment
These documents are available from your Emerson
 
 
 
 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
Honeywell TC-,TK-GE Modules IC -
ABB ModuleAB Module 1756-,1759- Tourch Screen 2711-
Mitsubishi Drive MR- , Motor HA -,HCEmerson MoudlesVE- ,KJ -
Fanuc motor A0-, DriveYokogawa transmitter EJA-
Rosemount Transmitter 3051-Schneider Module 140-
Panasonic Motor , Drive MH-Siemens Module 6ES-, Touch Screen 6AV-
 
 
 

Main technical parameter

Power supply: 12~30V DC; the controller has reverse polarity protection.(when HART is

communicating, the voltage of controller ≥17.75V DC)

Output signal: 4~20 mA DC (Positive direction the increase of level, interface, or density make output

increase; Negative direction the increase of level, interface, or density make output decrease.)

Measuring range: 300mm—2500mm (can also over range)

Nominal pressure: ≤42.0Mpa

Nominal diameter: DN40 or as customers request

Ambient temperature: 40ºC to +80ºC (when ≤30ºC, no LCD display)

Operating temperature: 70ºC to +400ºC

Measuring accuracy: 0.5%

Influence from power supply: When the voltage of the power supply varies between min. and max. ,the output change is within 0.2%. of the full scale.

LCD display: Output current signal,process variable,process temperature,percentage range,rotation angle of torque tube.

Medium density difference: ≥0.08g/cm³

Material of torque tube: Standard configuration Inconel 600,or Monel, HasetlloyC-276

Wetted material: 304,316L or as customers request

Flange standard: HG/T20592-2009,HG/T20615-2009 or as customers request

Power entry: Two NPT 1/2 (female thread) or as customers request

Explosion-proof: Explosion isolation ExdⅡCT6, Intrinsically safe ExiaⅡCT6

Protection grade: IP66

Alarm jumper: For the self-diagnosis to the inaccuracy failure of the process variables (for example, the electronic module failure). Configure the process variables of high and low alarms.

 

 

 

 

Using the Field Communicator, you can perform several operations with the DLC3010 digital level controller. You can interrogate, configure, calibrate, or test the digital level controller. Using the HART protocol, information from the field can be integrated into control systems or be received on a single loop basis.

DLC3010 digital level controllers are designed to directly replace standard pneumatic and electro-pneumatic level transmitters. DLC3010 digital
level controllers mount on a wide variety of caged and cagelss 249 level sensors. They mount on other manufacturers’ displacer type level sensors through the use of mounting adaptors.

249 Caged Sensors (see table 1-6)
249, 249B, 249BF, 249C, 249K, and 249L sensors side-mount on the vessel with the displacer
mounted inside a cage outside the vessel. (The 249BF caged sensor is available only in Europe, Middle East, and Africa.)
249 Cageless Sensors (see table 1-7)
249BP, 249CP, and 249P sensors top-mount on the vessel with the displacer hanging down into the vessel.
249VS sensor side-mounts on the vessel with the displacer hanging out into the vessel.
249W wafer-style sensor mounts on top of a vessel or on a customer-supplied cage.
 
 
 

Rosemount

3051CD0A02A1AB1H2L4M5

New

Rosemount

3051CD1A02A1AB1H2L4M5

New

Rosemount

3051CD2A02A1AB1H2L4M5

New

Rosemount

3051CD3A02A1AB1H2L4M5

New

Rosemount

3051CD4A02A1AB1H2L4M5

New

Rosemount

3051CD5A02A1AB1H2L4M5

New

Rosemount

3051TG1A2B21A

New

Rosemount

3051TG3A2B21AB4

New

Rosemount

3051TG1A2B21AB4M5K5

New

Rosemount

3051TG5A2B21AB4M5E5

New

Rosemount

3051TG5A2C21AB4M5K5

New

Rosemount

3051TA1A2B21AB4M5K5

New

Rosemount

3051TA3A2B21AB4M5E5

New

Rosemount

3051TA3A2B21AB4M5I5

New

 

Rosemount

3051GP1A2B21AB4M5

New

Rosemount

3051GP3A2B21AB4M5K5

New

Rosemount

3051GP4A2B21AB4M5E5

New

Rosemount

3051GP5A2B21AB4M5I5

New

Rosemount

3051CG1A02A1AB1H2L4M5

Rosemount

3051CG1A02A1AB3H2L4M5

Rosemount

3051CG4A02A1AB1H2L4M5K5

New

Rosemount

3051CG4A02A1AB1H2L4M5I5

New

Rosemount

3051CG5A02A1AB3H2L4M5I5

New

Rosemount

3051CA1A02A1AB1H2L4M5

New

Rosemount

3051CA2A02A1AB1H2L4M5K5

New

Rosemount

3051CA4A02A1AB1H2L4M5E5

New

Rosemount

3051CA5A02A1AB1H2L4M5I5

New

Rosemount

3051CA3A02A1AB3H2L4M5K5

New

Rosemount

3051CA5A02A1AB3H2L4M5K5

New

Rosemount

3051CA1A02A1AB3H2L4M5E5

New

 

 

 

 

 

FAQ

 

Q1. What about the lead time?

A: 3-5 days for Sample preparing ,8-10 working days for mass production.

 

Q2. Do you have any MOQ limit of Industrial Servo Drives?

A: Low MOQ, 1pc is available.

 

Q3. How do you ship the goods and how long does it take to arrive?

A: Ship by DHL, UPS, FedEx or TNT. It takes 3-5 days to arrive. Airline and sea shipping also optional.

 

Secondly, during the guarantee period, we will send new lights with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.

 

 

 

Hot Products

NEW EBMPAPST Centrifugal Cooling Fan R2E280-AE52-17 230V 50HZ 1.0A 225W 2700RPM in stock Description ...
MR-J2S-10B-S149 Mitsubishi Industrial Servo Drives 3 PHASE 3.5kw Servo Amplifier Descriptions of MR...
GE IC200PWR001 18 to 30VDC 24VDC nominal 11W 10ms high-density VersaMax IO is versatile Product ...
MR-J2S-40B-EE006 Mitsubishi Industrial Servo Drives 3 PHASE 400kw Servo Amplifier Product Descriptio...
DLC3010 Fihser HART 249W Digital Level Controller 12~30V DC digital level controller Specifications ...
50/60HZ Industrial Servo Drives YASKAWA SGDH-01AE SERVOPACK Brand New Quick detail: YASKAWA ELECTRIC ...