Force sensor torque transducer |
|
High Accuracy Weight Sensor 300g 600g 1000g 3kg Off Center Load Cell
Precision Low Range Off Center Load Cell Sensor FNA is a strain gauge based weight transducer which offers 0-300g / 0-600g / 0-1000g / 0-1500g / 0-3000g five measuring ranges to choose from. High accuracy weighing sensor FNA delivers maximum 0.02% non-linearity of the full capacity. Low capacity load cell FNA is corner trimmed for platform sizes up to 150x150mm which makes it suitable for off-center load measurement. Weight Transducer FNA delivers stable performance within the declared working temperature range thanks to its temperature compensation process. You may find Load Sensor FNA suitable for applications such as weighing balance, packaging machines, counting scales, feeding machines and so on.
Specifications
Rated capacity | 300g / 3N / 0.66lb 3000g / 30N / 6.6lb | ||
Sensitivity | 1.0 mV/V | Compensated temperature | -10...+40oC |
Excitation | 3-15V | Operating temperature | -20...+60oC |
Zero balance | ±0.05mV/V | Temperature shift zero | ±0.05% R.O./10oC |
Nonlinearity | ±0.02% R.O. | Temperature shift span | ±0.03% R.O./10oC |
Hysteresis | ±0.015% R.O. | Input resistance | 405±10 ohms |
Nonrepeatability | ±0.01% R.O. | Output resistance | 350±5 ohms |
Creep(30min) | ±0.03% R.O. | Insulation resistance | >2000Mohms |
Safe overload | 150% F.S. | Ingress protection | IP65 |
Ultimate overload | 200% F.S. | Material of element | Aluminum |
Cable | Ø4*250mm 4-core shielded | ||
Wiring code | Red--Power input+ Black--Power input- Green--Signal output+ White--Signal output- |
A weight sensor is a transducer that converts mechanical load into electrical signal which is proportional to the load being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV for low range load cell FNA. Overloading is the most common cause of loadcell failure, a load sensor is just like a spring in certain aspects, which will be damaged if overstretched or overloaded. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The deformation gap can be determined by loading the sensor with rated capacity, then adjust the meachnical stop to reach the bottom of the transducer. In most cases, the load cell will be used to measure load at 40-80% of the full capacity, thus the deformation gap can be adjusted using reference load a bit higher than the target load to be measured instead of the rated capacity.
High Accuracy Weighing Sensor 300g 600g 1kg 3kg Off Center Load Cell