Reverse Osmosis Plant 1TPH First Stage RO Water Treatment Equipment
 
Jufu Water Tech selects parts from famous foreign manufacturers, adopts advanced foreign processing technologies such as multistage pre-filtration, reverse osmosis, nuclear grade mixed bed resin purification, dual wavelength ultraviolet digestion, and our unique process design to ensure excellent performance and stability of products. Easy to operate and maintain. It can also be easily upgraded according to user needs.
 

Working Principle of Reverse Osmosis Water Treatment System:
 
When a pressure greater than osmotic pressure is applied on the saltwater side of the membrane, the flow of water is reversed and the water in the saltwater flows into the fresh side, a phenomenon called reverse osmosis.
 
Technical Specifications of Reverse Osmosis Water Treatment System:

1m³/h Reverse Osmosis System
ModelJFRO-1000L
Host Size1000x600x1600mm (can be customized)
Power2.2KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP
Pipe MaterialU-PVC/ Stainless steel (Optional)

 
Process flow of reverse osmosis water treatment system:
 
Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point

 
Reverse osmosis working principle:
Reverse osmosis is the most precise membrane liquid separation technology. The operating pressure on the inlet (concentrated solution) side is applied to overcome the natural osmotic pressure. When the operating pressure higher than the natural osmotic pressure is added to the concentrated solution side, the flow direction of the natural osmosis of water molecules will be reversed. Reverse osmosis equipment can block all soluble salt and molecular weight greater than 100 organic matter, but allow water molecules through, reverse osmosis composite membrane desalination rate is generally greater than 98%, they are widely used in industrial pure water and electronic ultrapure water preparation, drinking water production, boiler feed water and other processes, the use of reverse osmosis equipment before ion exchange can be significantly reduced operating water and wastewater emissions.
 
 
 

 
 

 

 
 

 
 

 
 

 
 

 
 
FAQ:
 
1, What are the inlet water quality requirements for ro water treatment system membrane components?

 
Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5 ≤4≤3

 
 
 
 
 
 
2. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
 
 
3. RO water treatment system configuration:
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
 
The arrangement of membrane components can be divided into series and parallel.





















































Hot Products

Reverse Osmosis Plant 1TPH First Stage RO Water Treatment Equipment Jufu Water Tech selects parts ...
500LPH Water Purifying System Two Stage Reverse Osmosis Pure Water Equipment Pretreatment: The ...
1TPH RO Water Treatment System FRP Pure Water Reverse Osmosis System Basic principle of reverse ...
100TPH RO Water Filter Equipment Purifying Water Filtration Plant Advantages of reverse osmosis ...
80TPH Water Purifier Reverse Osmosis System Waste Water Treatment Plant There are two ways to clean ...
Reverse Osmosis Water Purification Plant 500LPH Filtration System Single Stage Application fields of ...