Home Companies Jufu Water Technology Co., Ltd

Fully Automatic RO Water Treatment Equipment Water Purification Systems 6TPH

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

Fully Automatic RO Water Treatment Equipment Water Purification Systems 6TPH

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

Fully Automatic 6TPH RO Water Treatment Equipment Water Purification Systems

 

Reverse osmosis technology process

 

RO membrane itself is sensitive to the pH, temperature and specific chemicals of the influent. The water quality of the influent strictly requires the pH value range of 4~10, temperature <40℃, silt density index SDI<5, free chlorine <0.1mg·L-1, turbidity <1, iron content <0.1mg·L-1, etc. In order to meet the requirements of RO membrane water, raw water before entering the RO membrane system must first preprocessing (sedimentation, coagulation and microfiltration, ultrafiltration, activated carbon absorption, pH adjustment, etc.), then the pump pressure into the membrane module, the pressure under the action of raw water as water production through the RO membrane, and inorganic salts, organic matter and particle by RO membrane intercept on the other side of the membrane to form thick liquid. The concentrated solution can be recycled or reprocessed according to the requirements of the specific process. RO can be used with ultrafiltration, nanofiltration and other membrane devices to form an integrated membrane device.

 

Working Principle of Reverse Osmosis Water Treatment System:

 

When a pressure greater than osmotic pressure is applied on the saltwater side of the membrane, the flow of water is reversed and the water in the saltwater flows into the fresh side, a phenomenon called reverse osmosis.

 

Technical Specifications of Reverse Osmosis Water Treatment System:

 

ModelJFRO-6000L
Host Size2700x600x1600mm (can be customized)
Power3KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate67%
Designed Water Inlet3000L/h
Outlet Flow2000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes8
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP
Number of Membrane housing4
Pipe Material

U-PVC/ Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process flow of reverse osmosis water treatment system:

 

Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point

 

 

Unique Characteristics of Water Purification System Equipment:


1. The single-membrane desalination rate can reach 99%, the desalination rate of the primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of the secondary reverse osmosis system can generally be stabilized above 98%.
2. Because the reverse osmosis equipment can effectively remove microorganisms, organic substances and inorganic substances such as iron and silicon, the quality of the effluent is higher than other methods.
3. The equipment has small footprint, compact structure, reliable operation and convenient operation.
4. The system is simple, the degree of automation is high, the fault is automatically shut down, and it has the function of automatic protection.
5. The recovery rate can reach more than 70%.
6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAQ:

 

1, What are the inlet water quality requirements for ro water treatment system membrane components?

 

 

Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5 ≤4≤3

 

 

 

 

 

 

2. What is the material of ro water treatment system membrane?

 

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

 

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

 

 

3. RO water treatment system configuration:

 

First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

 

Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

 

The arrangement of membrane components can be divided into series and parallel.

Hot Products

Fully Automatic 6TPH RO Water Treatment Equipment Water Purification Systems Reverse osmosis ...
1000LPH RO Water Purification System Water Making Machine Automatic Reverse osmosis technology ...
Large Scale Ro Machinery 300TPH RO Water Treatment System Reverse osmosis system (RO Water Treatment ...
6TPH RO Water Treatment Equipment Reverse Osmosis Purifier Water System Reverse osmosis technology ...
200TPH Landfill leachate reverse osmosis treatment Water Filtration Plant Unique characteristics of ...
Small Size Water Filter 500LPH One Stage RO Water Treatment System Reverse osmosis technology ...