Jufu Water Technology Co., Ltd |
|
Commercial RO Water Treatment System 20TPH FRP Water Filter System
What contaminants will Ro Water Treatment System from the water?
Reverse osmosis can remove up to 99% of dissolved salts (ions),
particles, colloids, organics, bacteria and pyrogens from feed
water (but should not rely on RO systems to remove 100% of bacteria
and viruses). Reverse osmosis membranes filter contaminants
according to their size and charge. Any contaminant with a
molecular weight greater than 200 is likely to be rejected by a
properly functioning reverse osmosis system (water, by contrast,
has a molecular weight of 18). Similarly, the higher the ionic
charge of the pollutant, the more likely it is not to pass through
the RO membrane. For example, sodium ions have only one charge
(univalent) and are not repelled by RO membranes like calcium ions,
which have two charges. Again, this is why RO systems do not remove
gases such as CO2 very well, as they are not highly ionized
(charged) and have very low molecular weight in solution. Because
the RO system does not remove gases, the pH of the percolated water
may be slightly lower than normal as CO2 is converted to carbonic
acid, depending on the level of CO2 in the influent.
Technical specifications of Ro Water Treatment System
Model | JFRO-20T |
Host Size | 4500x1000x1700mm (can be customized) |
Power | 18.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 1.2~1.5MPa |
Recovery Rate | 67% |
Designed Water Inlet | 30t/h |
Outlet Flow | 20t/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304/Carbon Steel (Optional) |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 20 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 5 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Ro Water Treatment System Process Flow:
Raw water pump - sand filter - carbon filter - cartridge filter -
high pressure pump -RO membrane host machine -RO cleaning system
Reverse osmosis concentrated water treatment system features:
(1) Fast reaction rate, short processing time.
(2) a wide range of application, containing azo, carbon double
bond, nitro, halogenated structure and other difficult to degrade
organic matter has a good treatment effect.
(3) Simple process, long service life, low operating cost,
convenient operation and maintenance, stable treatment effect.
(4) High chroma and COD removal rate, improve the biodegradability
of RO concentrated water.
What is a Ro Water Treatment System?
The reverse osmosis water treatment system can separate, extract,
purify and concentrate the reverse osmosis method that is greater
than the osmotic pressure according to the different osmotic
pressures of various materials. When the RO membrane is located on
one side of the selective membrane, by applying pressure to the
solution, RO membranes remove many types of macromolecules and ions
from solution. Solutes such as iron, viruses, bacteria and solids
are retained on the pressurized side of the membrane, while pure
solvents are allowed to pass through the other side of the
membrane.
Working principle of Ro Water Treatment System
The reverse osmosis water treatment system is a reverse osmosis
equipment that squeezes the water molecules on one side of the
reverse osmosis membrane to the other side through a high-pressure
pump, then we can obtain pure water on the other side, which is the
most basic reverse osmosis technology. principle.
Photos and details of Ro Water Treatment System
FAQ:
1. What is the shell film material and specification of ro water
treatment system?
Material of membrane case: stainless steel and fiberglass (FRP)
Specification of membrane shell: four inch membrane shell 4040 (one
core to four core)
8 inch membrane case 8040 (one to seven cores)
Water inlet: end water inlet, side water inlet
2. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
3. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass