Home Companies Jufu Water Technology Co., Ltd

Water Reuse RO Water Treatment System 50TPH Water Filter System

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

Water Reuse RO Water Treatment System 50TPH Water Filter System

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

Water Reuse RO Water Treatment System 50TPH Water Filter System
 
Reverse Osmosis System Product Introduction:
 
High pressure pump, reverse osmosis membrane element, pressure vessel shell (membrane), cleaning system and control apparatus of the reverse osmosis system, reverse osmosis membrane pore size is small to nanoscale (1 nm = 10 to 9 meters), under the certain pressure, H2O molecules can pass RO membrane, and the source water of inorganic salt, heavy metal ions, organic matter, colloid, bacteria, viruses and other impurities through the RO membrane, Thus, pure water that can be permeated is strictly distinguished from concentrated water that cannot be permeated.
 
The Principle of Reverse Osmosis Water Treatment System


The raw water passes through the reverse osmosis membrane under the action of high pressure, and the solvent in the water diffuses from a high concentration to a low concentration to achieve the purpose of separation, purification and concentration. Because its permeation direction in nature is opposite, it is called reverse osmosis.
 
Technical Specifications of Reverse Osmosis Water Treatment System:
 

ModelJFRO-50T
Host Size7200x1500x1800mm (can be customized)
Power45KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure1.2~1.5MPa
Recovery Rate70%
Designed Water Inlet70t/h
Outlet Flow50t/h
Desalination Rate≥99.5%
RO FrameSUS304/Carbon Steel(optional)
Membrane Size8040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes54
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingFRP
Number of Membrane housing9
Pipe MaterialU-PVC/ Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
Process Flow of Reverse Osmosis Water Treatment System:
 
Raw water pump - sand filter - carbon filter - cartridge filter - high pressure pump -RO membrane host machine -RO cleaning system
 

 
Application Scope of Reverse Osmosis Water Treatment System


Residential and Villa Hotels/Hospitals Commercial Complexes Kinderney Dialysis Rooms Poultry Farms Food and Beverage Industry Bottled Water Plants Cooling Towers/Boiler Feed Water
 
Features of Reverse Osmosis Water Treatment System


1. The reverse osmosis pure water equipment adopts a fully automatic control method to realize automatic operation and reduce the influence of human error operation on the equipment belt;
2. In the pretreatment system, the design of the reduction system is adopted to solve the irreparable impact of excessive residual chlorine on the reverse osmosis membrane;
3. Imported reverse osmosis membrane is used in the selection of reverse osmosis membrane, the service life can reach 3 years, and the conductivity of effluent is lower than 10US/CM;
4. The southern special SUS304 stainless steel water pump is selected for the pump series, and the running noise is low;
5. Using foreign professional design software, the recovery rate can reach more than 65%;
6. It has the characteristics of high degree of automation, simple operation, stable water quality and low operating cost. And widely used in production water in various industries
 
Photos and details of Reverse Osmosis Water Treatment System

 

 

 

 

 

 

 

 

 

 

 


 
FAQ:
 
1, What are the inlet water quality requirements for ro water treatment system membrane components?

 

Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5 ≤4≤3

 
 
 
 
 
 
2. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
 
 
3. RO water treatment system configuration:
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
 
The arrangement of membrane components can be divided into series and parallel.
 

 

Hot Products

100TPH RO Water Treatment System For Landfill Leachate Treatment System Reverse osmosis (RO) systems ...
One Stage RO Water Treatment Plant Water Purification Machine For Well Water Reverse osmosis water ...
80TPH RO Water Treatment System FRP Pure Water Reverse Osmosis System Product introduction of RO ...
RO Water Treatment Plant Purified Water Machine for Pharmaceutical RO Water Treatment System ...
Water Reuse RO Water Treatment System 50TPH Water Filter System Reverse Osmosis System Product ...
Water Treatment Reverse Osmosis System Purifying Water Filtration Plant Unique characteristics of RO ...