JINPAT Electronics Co., Ltd |
Verified Suppliers
|
|
Dual-channel Slip Ring of 4.5GHz RF Coaxial Rotary Joint in Compact Signal Slip Ring
Description
RF Coaxial Connector refers to a device installed on the cable or instrument as transmitting or breaking the line of electrical connections. Also, it belongs to Mechanical & Electrical Integration product.
Coaxial connector refers to connecting two used by the end of shaft parts, to ensure the centerline of two axes on the same axis.It has many different advantages compared to traditional slip ring such as Low torque minimizes system torque budget, compact design to fit in the most demanding space, high bandwidth transfer capability and low electrical noise.It also provides quick shipment per your urgent requirement, still operating smoothly and reliably.
Commonly used to connect to the driving shaft and driven shaft, transfer the rotary motion of the drive shaft to the driven shaft.
Radio Frequency Specifications | |||||
Channel 1 | Channel 2 | ||||
Interface Type | SMA Female (50 ohms) | SMA Female (50 ohms) | |||
Style | I type | I type | |||
Frequency Range | DC to 4.5 GHz | DC to 4.5 GHz | |||
Peak Power, Max | 1500 W | 1500 W | |||
Average Power ,Max | 60 W @ 4.5GHz | 50 W @ 4.5GHz | |||
VSWR , Max. | 1.18 | 1.50 | |||
VSWR WOW (360°max) | 0.04 | 0.16 | |||
Insertion Loss , Max | 0.22 dB | 0.30 dB | |||
Insertion Loss ,WOW , max | 0.05 dB | 0.15 dB | |||
Phase WOW (degrees max) | 0.5° | 4.0° | |||
Isolation min. /typical | 50dB/60dB typical | ||||
General Mechanical and Environment data | |||||
Rotating Speed , Max | 60 rpm | Life , min. | 1x 107 revolutions | ||
Starting Torque | 5 Ncm max | Continuous Rotational Torque | 5 Ncm max | ||
Case material | Aluminum Alloy | Material contact /Finish | Beryllium Copper/Gold Plated | ||
Weight , approx | 131 g | Marking | Adhesive Label | ||
Temperature (Ambient Range) | -40 to +70℃ (Operation) | Humidity (Non-condensing) ,max. | 85% (Operation) | ||
-50 to +70℃ (Storage) | 95% (Storage) | ||||
IP Protection level | IP 60 per EN 60529 |
Outline Drawing