Portable Resistive Rack Mounted Load Bank 4 KW Power For Data Center

Hebei Kaixiang Electrical Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China

Contact name:

Inquir Now

Hebei Kaixiang Electrical Technology Co., Ltd

Portable Resistive Rack Mounted Load Bank 4 KW Power For Data Center

Country/Region china
City & Province shijiazhuang hebei
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

AC120/240V-4kW Rack Mounted Load Bank With Frequency 60HZ And Best Sales

Introduction

AC120/240-4kW Rack Mounted Load Bank, which can be used as terminal load test connectivity and reliability of power periodic line, safety of electric transmission line, battery.etc. Coordinate other power switchover. Also be used as simulate heat source of rack mounted server, test the air cooling system and air flow control.

Application

AC120/240V-4kW Rack Mounted Load Bank With Frequency 60HZ And Best Sales

When building a data center, any unexpected glitch during commissioning can cause serious project delays, wasted productivity, and significant budget overruns. So integrating rack mounted load banks into the design phase can help our data center clients keep projects on budget and on time.

Technical specification

Parameter
Rated voltage/frequencySingle phase120/240VAC/60Hz
Max Load PowerResisitive Power: 4kW(120V or 240V)
Load ResolutionResistive Load: 2 steps. A circuit 2kW; B circuit 2kW
Power Factor1
Load Tolerance+(0~10%)
Insulation GradeGrade F
Way of WorkingContinuous Working
CoolingForced air cooling, intake air in front and exhaust cooling in back
Case ColorBlack
Case DimensionAbout 430mm*600mm*178mm(L×W×H)
Weight

About 18kgs

About 18kgs

Operating Ambient Parameters

 

Ambient Temperature ttTeTemperatureTemperature

Temperature

-10℃~+40℃
Relative Humidity≤95%
Altitude≤2500 meters
Atmospheric Pressure86~106kPa
 
Main features

Work Indication : green means working power connect successfully.

Fault Indication: Red with alarm means the machine is under protection state.

Voltage change-over switch: When A circuit,B circuit connect 120V working power supply,switch point to【120V】;When A circuit, B circuit connect to 240V working power supply,switch point to【240V】.

Fan Power Switch:pull this switch upward, fan start to operate.

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

AC120/240V-4kW Rack Mounted Load Bank With Frequency 60HZ And Best Sales Introduction AC120/240-4kW ...
AC220-5 KW Rack Mounted Load Bank for data center Introduction 5kW Rack Mount Load Bank for Data ...
500 KW load bank for generator UPS transformer testing Introduction The system consists of 1 sets of ...
400V-600kW Portable Load Bank In Automatic And Grey Black Colour Introduction 1,AC400V-600kW ...
700kw Dummy Portable Load Bank 380VAC/50Hz With Grey Surface Introduction AC380-700kW is of ...
resistive load bank 800 KW for thailand Generator UPS testing Introduction AC400V-800KW Portable ...