ac variable load bank 1000 KVA adjustable Load Bank with ISO CE certificate

 

Introduction

 

(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-1000KVA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

 

Application

 

1 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.

 

2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

 

3 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

Technical specification

 

System Parameter
Rating voltage/frequency400V, 3 phase 4 wire 50Hz
Max Load Power

Apparent Power: 1000KVA

Resistive Load: 800kW

Inductive Load: 600KVAR

Load Resolution

Resistive Load: 12 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100k,200kW,200kW,200kW

Inductive Load: 11 steps

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR

Power Factor0.8(lag)
Load Tolerance (each step)±5%
Load Tolerance (overall)±3%
Fan &Control VoltageExternal AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication InterfaceRS485,RS232
InsulationF
Max Protection GradeIP21
Duty CycleContinuous
CoolingForced air cooling, by Fan; horizontal inlet air, horizontal exhaust cooling
TransportationHoisting, there are lifting lug in top of casing
ColorGrey RAL7035 or as required
DimensionAbout 2units* 2440 mm×1400mm×1680mm(L×W×H)(
Operating Environment Parameter
WorkplaceIndoor
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Atmospheric Pressure86~106kPa
 
Main features
(1) The load bank is made in container type, with hanging ring on top of container, easy to hoist and transport. There are processes of anti corrosion, anti salty spray and anti fungal according to requirement of easy sea-transported container. The case is sanded and derusted, sprayed with thermo-stable insulating coat, and sprayed with ship special paint outside. Considering cooling, hoisting transportation, components distribution and so on, load bank is treated with over heat and hot-dip galvanizing process, inner paint with high temperature paint. Bolts connect support brackets and bank. Components are well-distributed; each module is distributed with uniformity to make sure the proper weight distribution and cooling.

(2) The container is made by professional container manufacturer, which ensures that the production is strictly in accordance with the container’ manufacturing practice and relevant standards.

(3) The load bank adopts standard container, the overall error of fixing hole is ±2 cm, so that the container can reach the requirements in transportation and storage. The internal structure is a special design, which is divided into independent connection, resistance module, fan cooling, special insulation and so on.

(4) Container load bearing is designed in accordance with container design code. When detecting, use the special thickness gauge TT100 to detect the error of material thickness and design drawing, to ensure that the overall structure of the container meets the requirements of the load bearing. In general, the actual total weight of the load is only about 10T, only 1/3 of the load-bearing design, can ensure the safety and reliability of hoisting and moving.

 

 

 

 

Hot Products

ac variable load bank 1000 KVA adjustable Load Bank with ISO CE certificate Introduction (1) ...
600 KW resistive load bank with Intelligent Control For Thailand generator Testing Introduction 1. ...
300 KW ac variable load bank With 3 Phase 4 Wire load bank and ISO CE certificate Introduction AC400...
Professional Produce 1000kw resistive load to test generators Product Description The system ...
dummy load bank 500kw variable resistive load bank for brazil generator testing​ Introduction AC415V...
1200 KW ac load bank for brazil generator load bank for sale with ISO CE certificate General ...