VKL11 Earth Leakage Circuit Breaker(ELCB) type AC type A type ASi

1. General

1.1 Function

 

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.


1.2 Selection
 

Detectable wave form

 

ELCB TypeSuitable for electrical networks with
 Pulsated DC currentHarmonicsSwitching surges
AC CLASSNoNoNo
A CLASSYesNoNo
S, ASi CLASSYesYesYes
 

A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.
 

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

 

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

 

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

 


1.3 Approvals and certificates

We certify that the ELCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

 

Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay Si, G, KV
It ensures any tripping at least 10ms.
Si: Super immunised (High immunity to unwanted tripping).
Selective
It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.




ELCB | Earth Leakage Circuit Breaker

2. Technical parameters

 StandardIEC/EN 61008-1 AS/NZS61008.1
Electrical featuresModel No.VKL11
Poles2P, 4P
Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue2P: 240V 4P: 415V
Insulation voltage Ui415V
Rated frequency50/60 Hz
Rated residual making and breaking capacity I△m1500A
Short-circuit current Inc=I△c6000A, 10000A
Type (wave form of the earth leakage sensed)S
break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp4kV
Dielectric test voltage at ind. Freq. for 1 min2.5
Pollution degree2
Mechanical featuresElectrical life≥2000
Mechanical life≥2000
Fault current indicatorYes
Terminal protection degreeIP20

Ambient temperature (with

daily average ≤ 35℃)

-25℃ to 50℃
Storage temperate-30℃ to 70℃
InstallationTerminal connection typeCable/Pin-type busbar
Terminal size top/bottom for cable25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar10/16 mm²
18-8/18-5 AWG
Tightening torque2.5 N·m
22 In-Ibs.
MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
ConnectionFrom top and bottom



3. Outline and installation dimensions (mm)

ELCB | Earth Leakage Circuit Breaker

Product Description:

ELCB Earth Leakage Circuit Breaker

The ELCB Earth Leakage Circuit Breaker is a reliable and high-performing safety device that provides reliable protection against electric shock and fire hazards caused by earth leakage. It detects and disconnects the electric circuit in the event of earth leakage current exceeding the set limit.

a. we guarantee 5 years' warranty;

b. The material of ELCB shell is PA66 instead of bakelite (bakelite shell is easily broken when drop onto ground)

c. Bottom lock material is PA66 instead of iron with spring (iron lock with spring is easily broken and not nice looking)

d. Our quality control standard is very strict. We have perfect test equipment in our factory to tests products during production, all the ELCB will be tested and checked one by one at least 5 times before delivery.

e. VORAX has been certified by the ISO9001 Quality Management System, and all products produced in VORAX are kept in strict accordance with international IEC/EN standards.

f. VORAX products have gained variety of international certifications, including SAA, CB, CE, NF, SEMKO etc.

We are the only Chinese company who have ISI certificate for India.

We are the one of two companies who have NF certificate for France.

 

So if u buy our ELCB, the good quality of products is 100% guaranteed and you won't get any trouble with certificate issues. The price we quote is worth.

 

Features:

  • Product Name: ELCB Earth Leakage Circuit Breaker
  • Certificates: NF, SEMKO, VDE, KEMA, CE, ISI, UKCA
  • Trip Time: ≤0.1s
  • Rated Voltage: 240V/415V
  • Insulation Voltage: ≥2KV
  • Installation Method: Cable/busbar
  • ELCB Type: Type AC, type A, type ASiELCB Type EVF
 

Applications:

HAROK's VKL11 Earth Leakage Circuit Breaker (ELCB) is NF, SEMKO, VDE, KEMA certified and meets all safety requirements. It is designed for the protection of low-voltage electrical equipment and circuits against overloads and short-circuits and against earth leakage current. With a minimum order quantity of 1000, it is available in paper carton packaging and can be delivered within 4-6 weeks after payment. The operating environment humidity is ≤95%RH, with a temperature range of -25℃~+50℃, and it can be powered by a 50/60Hz rated frequency. It is easy to install via a fixed or plug-in method, with a material made of PA66. HAROK has a monthly production capacity of up to 100,000 pieces and offers FOB NINGBO or SHANGHAI payment terms.

The VKL11 ELCB provides a reliable protection solution for electrical systems and circuits. By using advanced safety technology, it can detect the presence of a fault current to earth and operates to disconnect the circuit when a fault is detected. This helps to prevent harm due to electric shock, short circuits, and overloads. It is a cost-effective protection device suitable for a variety of applications, such as for use in homes, offices, factories, and other commercial and industrial settings.

 

Technical Parameters:

NameElectric Leakage Circuit Breaker (ELCB) 
CertificateNF, SEMKO, VDE, KEMA, CE, ISI, UKCA
Operating Environment Temperature-25℃~+50℃
DimensionAccording To The Product Model
Rated Sensitivity30mA/100mA/300mA
Trip Time≤0.1s
Rated Voltage240V/415V
Rated Frequency50/60Hz
Protection GradeIP20
WeightAccording To The Product Model
Rated Breaking Capacity10KA
 

Customization:

ELCB Earth Leakage Circuit Breaker
  • Brand Name: HAROK
  • Model Number: VKL11
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA
  • Minimum Order Quantity: 1000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Payment Terms: FOB NINGBO or SHANGHAI
  • Supply Ability: 100,000 PCS PER MONTH
  • Insulation Voltage: ≥2KV
  • Material: PA66
  • Installation Method: Cable/Pin-type busbar
  • Weight: According To The Product Model
  • Operating Environment Temperature: -25℃~+50℃
 

Packing and Shipping:

Packaging and Shipping of ELCB (Earth Leakage Circuit Breaker)

ELCB products should be packaged in cardboard boxes, bubble wrap, or other appropriate materials. All packages must be sealed with a tamper-evident label to prevent tampering and to ensure the contents are safe and secure during transport.

When shipping ELCB products, the packages must be clearly labeled with the product name, model number, and destination address. The shipper must also provide tracking information so that the receiver can track the package during transit.

In addition, all packages must be shipped according to the applicable laws and regulations of the country of origin and destination. It is also important to make sure that the packages are insured for any potential damage or loss during transit.

Hot Products

VML01 Earth Leakage Circuit Breaker Inmetro 1. General 1.1 Function Control electric circuits. ...
VFL001 Earth Leakage Circuit Breaker(ELCB) Type A Type AC Type ASi 1. General 1.1 Function Control ...
VML01 Earth Leakage Circuit Breaker Type A Type AC Type ASi 1. General 1.1 Function Control electric ...
VKL11 Earth Leakage Circuit Breaker(ELCB) type EV 1. General 1.1 Function Earth Leakage Circuit ...
VKL11 Earth Leakage Circuit Breaker(ELCB) type AC type A type ASi 1. General 1.1 Function Control ...
VKL11 Earth Leakage Circuit Breaker(ELCB) type G sort-time delay 1. General 1.1 Function Control ...