Home Products Personal Care Beauty Equipment

ray detector ultrasound probe repair

Refine Search
Results forray detector ultrasound probe repairfrom 8862 Products.
Hitachi EUP-C715 Surgical Instruments Convex Abdominal Repair Ultrasound Probe 1.Model: EUP-C715 2.Repair Time: 2-5 days 6.With 60 days warranty Parts of GE probes we can offer: ...
Guangdong, china
Verified
Refurbished Toshiba PLT-704AT Ultrasound probe 6-11MHz frequency Linear array Description: The Toshiba PLT-704AT linear ultrasound transducer is compatible with Toshiba aplio/viamo...
Guangdong, china
Verified
Hitachi EUP-C715 Surgical Instruments Convex Abdominal Repair Ultrasound Probe 1.Model: EUP-C715 2.Repair Time: 2-5 days 6.With 60 days warranty Parts of GE probes we can offer: ...
Guangdong, china
Verified
Dual Frequency Toshiba PVG-366M Convex array ultrasound probe for Abdominal application Description: The Toshiba PVG-366M is a dual frequency convex ultrasound transducer. The PVG...
Guangdong, china
Verified
GE M5SC-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair ​Model: GE M5SC-D Fault Phenomenon: Cable and strain relief are aging, lens bubbling. ...
Guangdong, china
Verified
Probe Miantenance GE RIC6-12-D Repair 4D Dome Replacement GE RIC6-12-D Repair 4D and Dome Replacement Model: GE RIC6-12-D Fault Phenomenon: Error reported in the 4D, oil sac ...
Guangdong, china
Verified
Probe Miantenance GE RIC5-9-D Repair 4D Replace Dome and Crystal Array GE RIC5-9-D Repair 4D Replace Dome and Crystal Array Model: GE RIC5-9-D Fault Phenomenon: The image is ...
Guangdong, china
Verified
GE L4-12T-RS Ultrasound Transducer Lens Replacement ​Model: GE L4-12-RS Fault Phenomenon: Cable and strain relief are aging, lens bubbling. Maintenance Plan: Replace lens (the ...
Guangdong, china
Verified
Siemens 18L6 Ultrasound Probe Repair Service Crystal Array Replacement Model: Siemens 18L6 Fault Phenomenon: The cable is yellow, the image on the machine has a dark shadow, and ...
Guangdong, china
Verified
Ultrasound Transducer Repair Service GE RIC5-9W-RS Replace Dome and Oil Filling Model: GE RIC5-9W-RS Fault Phenomenon: The dome is damaged and oil leakage, there are no obvious ...
Guangdong, china
Verified
Ultrasound Transducer Repair Service GE 8C-RS Acoustic Lens Replacement Model: GE 8C-RS Fault Phenomenon: The connector cable and strain relief are aging, the image on the computer ...
Guangdong, china
Verified
Probe Repair GE 4C Convex Probe Ultrasound Transducer Miantenance Model: GE 4C Fault Phenomenon: The cable is aging and broken, the strain relief is aging, the connector housing ...
Guangdong, china
Verified
Probe Maintenance for GE IC5-9-D Ultrasound Transducer Replace the Original Crystal Model: GE IC5-9-D Fault Phenomenon: The cable is aging and discolored, the housing cover is worn ...
Guangdong, china
Verified
Probe Maintenance for Philips L12-3 Ultrasound Transducer Strain Relief/Crystal and Connector Cable Replacement Model: Philips L12-3 Fault Phenomenon: The cable and strain relief ...
Guangdong, china
Verified
GE RIC5-9-D Probe Repair Maintence for Diagnosis Equipment- Replace Lens, Replace oil sacs, refill oil, replace housing The main components of a typical ultrasound transducer 1 ...
Guangdong, china
Verified
Repair Toshiba PVU-375BT Lens/Lens Replacement/Repair Service The lens of failures Reasons An acoustic lens is a gelatinous professional substance that ultrasound probe contacts ...
Guangdong, china
Verified
GE 4C-D Probe Repair Maintence for Diagnosis Equipment- Replace Lens, Replace oil sacs, refill oil, replace housing The main components of a typical ultrasound transducer 1 Lens 2 ...
Guangdong, china
Verified
GE RIC5-9W-RS 4D Monitor Strain Relief Repair Service Ultrasound Probe 1. Type: Microconvex 2.Compatible system: Voluson i, Voluson e, Voluson S8, Voluson S10, Logiq S6 , Logiq P6 ...
Guangdong, china
Verified
GE RIC5-9-D Repair 4D Replace Dome and Crystal Array Model: GE RIC5-9-D Fault Phenomenon: The image is seriously missing, 4D doesn't work Suggestion: Repair 4D and Replace the Dome ...
Guangdong, china
Verified
Repair 4D V6-2 IU22/IE33 Cable/Connecting Cable Leakage/Damaged Cable Cable leakage failure reason and solution Ultrasound probe cable is adopted by high quality of high multi...
Guangdong, china
Verified
Page 5 of 50 |< << 1 2 3 4 5 6 7 8 9 >> >|