Home Companies Hangzhou Aichek Medical Technology Co.,Ltd

CE 99.05% Rapid Antigen Self Test 1pc Lateral Flow Antigen Test Kit

Hangzhou Aichek Medical Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: 3rd Floor, Building 9, Hexiang Technology Center, Xiasha Street, Qiantang District, 310018 Hangzhou, Zhejiang, P.R. China

Contact name:Edward YU

Inquir Now

Hangzhou Aichek Medical Technology Co.,Ltd

CE 99.05% Rapid Antigen Self Test 1pc Lateral Flow Antigen Test Kit

Country/Region china
City & Province hangzhou zhejiang
InquireNow

Product Details

Selftest COV-19 Rapid Lateral Flow Antigen Test Kit ,

Ce Approval Rapid Antigen Kit Test

Product Name

Selftest COV-19 Rapid Lateral Flow Antigen Test Kit

FormatsDevice(4mm)
Place of OrigenChina
SpecimenSwab
Read Time15 minutes
Shelf life2 years
Package25 device/box or 1Test/Box
Storage2℃-30℃

 

The COVID-19 Antigen Rapid Test device is a lateral flow chromatographic immunoassay for the qualitative detection of the nucleocapsid(N) protein antigen from SARS-CoV-2 in nasopharyngeal swab, oropharyngeal swab. It provides an aid in the diagnosis of infection with 2019-nCOV.

 
[QUALITY CONTROL]
A procedural control is included in the test. A colored line appearing in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify propertest performance.
 
 

[WARNINGS AND PRECAUTIONS]
l For in vitro diagnostic use only.
l For healthcare professionals and professionals at point of care sites.
l Do not use after the expiration date.
l Please read all the information in this manual before performing the test.
l The test device should remain in the sealed pouch until use.
l All specimens should be considered potentially hazardous and handled in the same manner as an infectious agent. Wear gloves

ifneed, don’t touch the membrane.
l The used test device should be discarded according to federal, state and local regulations.
l The test is intended to be read at 15 minutes. If the test is read before 15 minutes or after 20 minutes, false negative or false positive

results may occur, and the test should be repeated with a new test cassette.
l The test device is a disposable product. Please dispose properly after use.

 

Hot Products

SARS-CoV-2 IVD Reagent Rapid Antigen Self Test Kit Individual Test Product Name SARS-CoV-2 IVD ...
Clinical Use Covid 19 Self Swab Test Kit for qualitative detection Product Name Clinical Use Covid ...
Antigen Covid 19 Self Swab Test Kit For Private Use Product Name Antigen Covid 19 Self Swab Test Kit ...
High Sensitivity CoV-19 Antigen Detection Kit 25PCS One Step Rapid Test Kit Product Name High ...
Selftest COV-19 Rapid Lateral Flow Antigen Test Kit , Ce Approval Rapid Antigen Kit Test Product ...
Quick check ISO13485 Saliva Antigen Rapid Test Kit 25pc Rtk Ag Saliva Product Name Quick check ...