Home Companies Xi 'an West Control Internet Of Things Technology Co., Ltd.

NYRD705 1.8GHz Guided Wave Radar Level Meter Measuring Range 6m

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Block V5, Ronghao Industrial Town, Gaoling District, Xi'an City, Shaanxi Province

Contact name:Gao

Inquir Now

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

NYRD705 1.8GHz Guided Wave Radar Level Meter Measuring Range 6m

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

 

NYRD705  1.8GHz Guided Wave Radar Level Meter 

 

Guided wave radar level gauge, a level measuring instrument in chemical industry. Guided wave radar level meter is a radar level meter based on the principle of time domain reflectometry (TDR). The electromagnetic pulse of the radar level meter travels along the cable or probe rod at the speed of light. When it meets the surface of the measured medium, part of the pulse of the radar level meter is reflected to form an echo and returns to the pulse transmitter along the same path. The distance between the launcher and the surface of the measured medium is proportional to the propagation time of the pulse in the meantime, and the height of the liquid level is calculated.

 

Radar Level Meter Technical Parameter

 

Typical applicationLiquids, powders, solid particles, corrosive media
Antenna materialFlexible cable/304/PTFE (optional)
Measuring range6 m
Accuracy±1mm
Power supply24 VDC(Two-wire,Four- wire)
Medium temperature -40~+130℃,-40~+250℃
Pressure -0.1~4.0MPa
Process connectionThread, Flange (optional)
Protection classIP67
Explosion-proof gradeExiaⅡCT6(optional)
Signal output4...20mA/HART/RS485/Modbus...

 

 Note: Products can be customized according to the specific requirements of users!

 

Radar Level Meter Operating Principle

 

The high-frequency microwave pulse emitted by the guided wave radar propagates along the detection component (steel cable or steel rod), and when it encounters the measured medium, due to the sudden change of the dielectric constant, it causes reflection, and a part of the pulse energy is reflected back. The time interval between the transmitted pulse and the reflected pulse is proportional to the distance of the measured medium.

 

Radar Level Meter Installation requirements

 

Standard installation method

 

 

◎ It is recommended to install at 1/4 or 1/6 of the container diameter.
Note: The minimum distance from the tank wall is L0≥300mm, H0≥50mm.
◎ Keep away from the inlet and outlet.
◎ Keep clear of obstacles such as limit switches, heating coils, agitators, etc. Note: The distance between the probe and the obstacle is ≥200mm.
◎ When the container is a metal can, the radar should not touch the wall and bottom of the can in the whole range.
◎ If the bottom of the container is tapered, the radar can be installed in the center of the top of the tank.
◎ The height of the installation short pipe should be L1≤10cm.

 

Radar Level Meter Electricalconnections

 

◎ Supply voltage


(4 ~20)mA/HART(Two-wire)
The power supply and the output current signal share a two-core shielded cable. Refer to the technical data for the specific supply voltage range. For the intrinsically safe type, a safety barrier must be added between the power supply and the instrument.

 

(4~20)mA/HART(Four-wire)
The power supply and the current signal are separated, and each uses a two-core shielded wire. Refer to the technical data for the specific supply voltage range.

 

RS485/Modbus
The power supply and the Modbus signal are separated, and each uses a two-core shielded wire. For specific supply voltage range see technical data .

 

◎ Connection method

 

 

◎ Explosion-proofconnection

 

 

Radar Level Meter SelectionTabel

 

For example: NYRD705-AC1A33VAPM1000

 

Manufacturer number
NYRD
Product model
705 Range 6m
Antenna form/ Size/ Material

A

B

Y

Cable antenna/ 304

Cable antenna/ PTFE Special Customized

Process connection
AThread: G1½A
BThread: G1A
CThread: G¾A
DThread: 1½NPT
EF l a n g e : DN50
FFlange: DN80
GFlange: DN100
YSpecial customized
Output/Supply

1 4~20mA/24VDC Two-wire

2 4~20mA/24VDC/Hart Two-wire

3 4~20mA/220VAC/Hart Four-wire

4 RS485/Modbus

Live display/ Programming
A XWith Without
Nuoying code
XX
Process temperature
1 - 40~+ 130℃
2 - 40~+ 250℃
3 - 40~+ 500℃
Y Special customized
Process pressure
1 - 0.1~+ 0.3MPa
2 - 0.1~+ 2.0MPa
3 - 0.1~+ 4.0MPa
Y Special customized
Sealing

V Viton

K Kalrez

Y Special customized

Housing material/ protection level
A Aluminum/ IP65
D Aluminum ( Dual Cavity)/ IP67
S SS 304/ IP68
Y Special customized
Explosion-proof grade
P Standard
L Exia IICT6
G Exd[ia] IICT6 Special
Y customized
Cable entry

M M20×1. 5 N 1/ 2" NPT

Y Special customized

Range ( unit: cm)
X ......

 

Hot Products

NYRD704 1.8GHz Guided Wave Radar Level Meter The guided wave radar level meter is a level meter ...
NYRD705 1.8GHz Guided Wave Radar Level Meter Guided wave radar level gauge, a level measuring ...
NYRD702 1.8GHz Guided Wave Radar Level Meter The guided wave radar level meter is a level meter ...
NYRD701 1.8GHz Guided Wave Radar Level Meter The guided wave radar level meter is a level meter ...
NYRD703 1.8GHz Guided Wave Radar Level Meter Level Transmitter Measurement Of Low Dielectric ...
80GHz Continuous Frequency Modulation Wave Radar Level Meter,Measuring Range:0~20m,0~40m,0~80m...