Membrane Nitrogen Generator Introduction
N2 and O2 all have a quadrupole, for the reason that the quadrupole
of N2(0.31 Å)is bigger than the quadrupole of O2 (0.10 Å), the
adsorption capacity by molecular sieve to N2 is stronger than O2.
When the compressed air in certain pressure flow through adsorption
bed formed by molecular sieve,
the N2 gas is absorbed and O2 is obtained by separation.
The main part of O2 generator is two towers filled with molecular
sieve , when the compressed air get into adsorption tower, the N2,
is absorbed by molecular sieve, N2 is produced from the export
terminal . When one tower produces N2, another tower release the N2
by reducing the pressure to get the renewable desorption of carbon
molecular sieve. Two towers alternate adsorption and regeneration
to output N2 continuously.
Membrane Nitrogen Generator Feature:
(1) Nitrogen Generator
1.1) High purity
1.2) Excellent energy-saving
1.3) Smoothly running,long-life
1.4) Automatic operating
1.5) Certificate:ISO9001:2008
Membrane Nitrogen Generator Specifications:
No | Model | Capacity(Nm3/h) | Purity | Power(KW) | Overall size(mm) |
1 | PN-3-39 | 3 | 99.9% | | |
5 | PN-5-49 | 5 | 99.99% | | |
9 | PN-10-49 | 10 | 99.99% | | |
13 | PN-15-49 | 15 | 99.99% | 0.5 | 2100*1800*2200 |
17 | PN-20-49 | 20 | 99.99% | 0.5 | 2200*1800*2200 |
21 | PN-30-49 | 30 | 99.99% | 0.5 | 2400*1900*2200 |
25 | PN-40-49 | 40 | 99.99% | 0.5 | 2500*2100*2500 |
29 | PN-50-49 | 50 | 99.99% | | |
33 | PN-60-49 | 60 | 99.99% | | |
37 | PN-80-49 | 80 | 99.99% | 0.5 | |
38 | PN-120-39 | 120 | 99.9% | | |
... | ... | ... | ... | ... | ... |
Note:More news please free to contact Since Gas System Co.,Ltd or send email to us directly |
Membrane Nitrogen Generator Technical characteristics
1. Unique molecular sieve protective measures so as to lengthen the
service life of carbon molecular sieve.
2. Self-reliance type cylinder pressure device can avoid high-speed
airflow rushed out , it can not cause of molecular sieve
pulverization phenomenon. equipped with the limit settlement alarm
system,when it reach the floor level of journey,the equipment will
sound and light alarm by itself.
3. Configured DCS remote control system interface,it can monitor
the system operate condition through the computer.
4. Intelligent interlocking nitrogen vent device can guarantee the
quality of nitrogen.
5. Perfect process design and excellent energy conservation
characteristics reduce the cost of gas.
6. Reasonable structure design make the transportation, sling and