Home Companies Eco-Tech Suzhou Limited

65Nm3/H Portable Oxygen Concentrator Continuous Flow Medical Oxygen Generation Plant

Eco-Tech Suzhou Limited

Contact Us

[China] country

Trade Verify

Address: Building 9, Senpu Industrial Park, No.25, Hangdu Road, Pudong New Area

Contact name:Melissa

Inquir Now

Eco-Tech Suzhou Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

65Nm3/H Portable Oxygen Concentrator Continuous Flow Medical Oxygen Generation Plant

Country/Region china
InquireNow

Product Details

93% Purity 65Nm3/H PSA Oxygen Genertor Continuous Flow Po/rtable Oxygen Concentrator
Description for PSA Oxygen Generator
PSA Oxygen Generator is consisted of the screw air compressor, air dryer, filters, buffer tanks, oxygen
generator, electricity control system and the optional oxygen cylinder filling station. The complete system is installed and tested at factory, delivery to customer's turn-key project.
PB containerized oxygen g
enerator is removable, and makes the onsite installation and operation very easy. It can also save the cost for the decoration cost of the machine room.

 

Main Features for PSA Oxygen Generator

  • Runs automatically without human intervention
  • Routine maintenance reminder and 10 years spares parts available
  • Complete support, from installation to debugging to training to support
  • End-to-end monitoring of pressure, purity, flow rate and alarm function.
  • Quiet, safe and energy efficient
  • Automatic discharge of unqualified gas
  • PID output function
  • Emergency Stop Control
  • All the tubing is in stainless steel bright tube ensuring a bactericidal action


PB PSA Oxygen Generator Model Select

Range of the PSA Oxygen Generator
ModelO2 Flow (Nm3/h)O2 Flow (LPM)Equivalent cylinder-7m3(per day Nos)Power With booster(Kw)Power Without HPBC(Kw)PurityLoading
PB-55831713993%±3%LCL
PB-1010167342216.593%±3%LCL/20GP
PB-1515250512820.593%±3%LCL/20GP
PB-202033368433293%±3%20HQ/40HQ
PB-252541785433293%±3%20HQ/40HQ
PB-3030500102554093%±3%20HQ/40HQ
PB-4040667136634893%±3%40HQ
PB-50508331707657.593%±3%40HQ
PB-656510832211017993%±3%40OT
PB-8080133327214511593%±3%40FR
PB-9090150030618114493%±3%40FR
PB-100100166734021417793%±3%40FR
PB-120120200040824720393%±3%40FR+20GP
PB-150150250051026321893%±3%40FR+20GP


Working Principles for PSA Oxygen Generator

  • Air contains 21% Oxygen, 78% Nitrogen, 0.9% Argon and 0.1% other trace gases. Oxygen plant separates this oxygen from Compressed Air through a unique process called Pressure Swing Adsorption. (PSA).
  • The Pressure Swing Adsorption process for the generation of enriched oxygen gas from ambient air utilizes the ability of a synthetic Zeolite Molecular Sieve to absorb mainly nitrogen. While nitrogen concentrates in the pore system of the Zeolite, Oxygen Gas is produced as a product.
  • Oxygen generation plant's use two vessels filled with Zeolite Molecular sieve as adsorbers. As Compressed Air passes up through one of the adsorbers, the molecular sieve selectively adsorbs the Nitrogen. This then allows the remaining Oxygen to pass on up through the adsorber and exit as a product gas. When the adsorber becomes saturated with Nitrogen the inlet airflow is switched to the second adsorber. The first adsorber is regenerated by desorbing nitrogen through depressurization and purging it with some of the product oxygen. The cycle is then repeated and the pressure is continually swinging between a higher level at adsorption (Production) and a lower level at desorption (Regeneration).

 

PB-65 PSA Oxygen Plant Technical Specification
lotItemDescription /Specification
1Model/Place of ManufacturePB-65China
2Oxygen making principlePSA Pressure swing adsorption PSA变压吸附(开放式结构)
3ApplicationOperation placeIndoor
EnvironmentAmbient temperatureMin -5℃/Max 50℃/ design temperature37℃
Ambient humidityMin 40%RH Max90%RH
4Capacity65Nm3/hr
5Oxygen Gas Purity93% ±3% Test at outlet of psa oxygen generator
6Oxygen Purity SensorHT-TA530 1set
7Oxygen FlowmeterJapan SMC flowmeter 1 sets
8Inlet compress air pressure0.55~0.7 Mpa
9Inlet Oil Content≤0.001mg/m3
Residual dust≤0.01um
Residual water≤0.069mg/m3
10Air inlet atmospheric dew point-15℃
11Demand for clean compressed air13.0 m³/minRecommend Air compressor75Kw 13.1 m³/min 8Bar
12Inlet DiameterDN40
13Outlet DiameterDN25
14Maximum inlet temperatureMAX 30 ℃
15Allowable working pressure rangeMin7.5Kgf / cm2 Max9.9Kgf / cm2
16Carbon molecular sieve model/originJLOX-500
17The tower body pipe2 sets
18Air and Oxygen buffer tankPiped storage tank
19Instrument Tank, silencerPB Silencer ≤55dB(A)
20Solenoid valve brand/originAirTAC9 sets
21Pneumatic valve brand/originPowerbuilder9 Sets+2 Sets
22Control SystemControl Power Supply0.2kw/set 220V 50 HZ
PLCSiemens PL Smart S7-200 or Mitsubishi integrated PLC
Electrical boxbuilt-in1 set
Touch screenMCGS 7 inch or Mitsubishi integrated PLC with screen
23size LxWxH (mm) / Weight:(Kg)About:2000*1400*2550// 1800kg

-Standard Features -

  • Control system with SIEMENS touch operated panel
  • Automatic start/stop
  • Built in purity analyzer for continues monitoring
  • Reliable- built for uninterrupted operation
  • Designed for dynamic pressure loading
  • Robust design, piping from Stainless Steel


-Optional Features-

  • Molecular sieve moisture protection
  • GSM modem (remote start/stop, status SMS, alarm warning SMS)
  • Flow meter with totalize
  • Oxygen dew point sensor
  • Temperature sensor
  • Purity and pressure control
  • Audio/visual alarm
  • Modbus TCP/IP connection
  • Remote control system
  • Data-logging (saved on memory card)


-Applications-

  • Aquaculture
  • Feed Gas for Ozone Generators
  • Glass blowing
  • Leaching
  • NOx Reduction for Fuel Burners
  • Oxygen Lancing
  • Welding, Brazing
  • Wellness

­­­­­

Ten frequently asked Questions about PSA oxygen generators

1.What is a PSA oxygen concentrator?

A PSA oxygen concentrator is a device that separates and purifies high-purity oxygen from the air using pressure swing adsorption (PSA) technology. It utilizes molecular sieve adsorbents to achieve the separation and purification of oxygen based on the differential adsorption properties of oxygen and nitrogen in the molecular sieve.

2.How does a PSA oxygen concentrator work?
The working principle of a PSA oxygen concentrator is based on the adsorption properties of the molecular sieve. It cycles compressed air and passes it through the bed of molecular sieve adsorbents. Nitrogen molecules are adsorbed onto the sieve, while oxygen molecules pass through, thereby achieving the separation and purification of oxygen.

3.What are the advantages of a PSA oxygen concentrator?
PSA oxygen concentrators have several advantages:

They can generate oxygen on-demand in real-time, eliminating the need for oxygen storage.
They are easy to operate and maintain.
They can be used indoors without the need for external gas pipelines.
They produce high-purity oxygen, suitable for medical-grade applications.
4.What are the main uses of a PSA oxygen concentrator?
PSA oxygen concentrators are widely used in medical, pharmaceutical, food processing, and electronic industries. They provide high-purity oxygen to meet the requirements of various industries and applications, such as oxygen therapy in hospitals and oxygen combustion in industries.

5.What is the oxygen purity achievable with a PSA oxygen concentrator?
Typically, PSA oxygen concentrators can provide oxygen with a purity of 93% or higher. For specific requirements, the oxygen purity can be further increased through additional oxygen purification processes.

6.Does a PSA oxygen concentrator require maintenance?
Yes, PSA oxygen concentrators require regular maintenance and servicing to ensure their proper operation and extended lifespan. Maintenance tasks include cleaning filters, inspecting, and replacing adsorbents, among others.

7.What is the noise level of a PSA oxygen concentrator?
PSA oxygen concentrators generally have low noise levels, typically below 50 decibels. However, the noise level may vary depending on the model and brand of the concentrator, but most are designed to operate quietly.

8.Does a PSA oxygen concentrator require a power source?
Yes, PSA oxygen concentrators require a power source to function properly. Typically, they need to be connected to a 220V AC power supply with a frequency of 50Hz.

9.Does a PSA oxygen concentrator need a compressed air source?
Yes, a PSA oxygen concentrator needs to be equipped with a compressed air source. It uses compressed air as the oxygen feedstock for its operation.

10.Is it necessary to frequently replace the adsorbents in a PSA oxygen concentrator?

  • Adsorbents play a crucial role in the functioning of a PSA oxygen concentrator, and they typically have a long lifespan that can span several years. However, as the concentrator is used over time, the adsorbents gradually become less effective at separating nitrogen from oxygen, necessitating periodic checks and replacements.
  • The actual replacement cycle for the adsorbents can vary depending on factors such as the frequency and duration of usage, as well as the specific model of the oxygen concentrator. To ensure the optimal performance of the concentrator, it is important to follow the manufacturer's guidelines and recommendations for checking and replacing the adsorbents.
  • Manufacturers of PSA oxygen concentrators typically provide guidelines and recommendations on when and how to assess the condition of the adsorbents and determine if they need replacement. These guidelines help users maintain the concentrator's efficiency and effectiveness over time.
  • The assessment of adsorbent condition may involve various methods, including visual inspections, pressure and flow rate measurements, or other diagnostic techniques. By following the manufacturer's guidelines and performing these assessments at the recommended intervals, users can ensure that the adsorbents are replaced when necessary, thereby preserving the concentrator's performance.
  • Regularly checking and replacing the adsorbents is crucial for maintaining the consistent production of high-purity oxygen. Over time, adsorbents can become saturated with nitrogen and lose their ability to separate oxygen effectively. If not replaced in a timely manner, this can lead to decreased oxygen purity levels, reduced efficiency, and compromised overall performance of the concentrator.
  • To obtain accurate information and specific guidance on checking and replacing the adsorbents, it is advisable to consult the user manual provided by the manufacturer or reach out to them directly. Authorized service providers can also offer valuable assistance in understanding the replacement process and ensuring the continued reliable operation of the PSA oxygen concentrator.
  • By adhering to the manufacturer's guidelines and regularly assessing and replacing the adsorbents, users can maintain the performance and longevity of their PSA oxygen concentrators. This proactive approach ensures the consistent delivery of high-purity oxygen and supports the optimal functioning of the concentrator in various applications and industries.

 

 

Hot Products

93% Purity 20Nm3/H PSA Oxygen Genertor/Pure Oxygen Generator/medical grade oxygen generator/ ...
93% Purity 90Nm3/H PSA Oxygen Genertor Continuous Flow Po/rtable Oxygen Concentrator Description for ...
93% Purity 65Nm3/H PSA Oxygen Genertor Continuous Flow Po/rtable Oxygen Concentrator Description for ...
93% Purity 80Nm3/H Portable Oxygen Equipment/Portable Oxygen Units/Oxygen Manufacturing Machine/ ...
93% Purity 50Nm3/H Psa Oxygen Gas Plant/oxygen generator machine/industrial oxygen plant Description ...
93% Purity 40Nm3/H PSA Oxygen Genertor Continuous Flow Po/rtable Oxygen Concentrator Description for ...