Zhejiang THOR Electric Co., Ltd |
|
Photovoltaic DC lightning protector, DC1000V20-40KA surge protector, solar power lightning arrester.
Brief introduction
Toer solar PV lightning protection device is designed and
manufactured according to IEC and GB standards, and meets
IEEE802.3AT requirements. We choose brand components with advanced
production technology. It has the characteristics of large flow
capacity, low residual pressure level, sensitive reaction, stable
performance, reliable work and so on. What weather can be used at
ease, ease of use, and no need to worry about what harm
thunderstorms do.
Working principle of product
In the solar photovoltaic system, the inductive or
capacitive coupling voltage is caused by the lightning shock and
the switching operation of the upstream power supply system.
Therefore, the surge may damage the photovoltaic modules and
inverters, which will cause serious consequences for the operation
of the photovoltaic system. The photovoltaic lightning arrester is
specially developed for this purpose. The lightning protection
module of the DC power supply, once the high voltage, and endanger
the insulation of the protected equipment, the lightning arrester
acts immediately, and the high voltage impact current is directed
to the earth, thus limiting the amplitude of the voltage and
protecting the insulation of the equipment. When the overvoltage is
gone, the arrester is restored to its original state quickly, so as
to protect the power equipment.
Product features
1. thunderbolt counting function, easy to understand
the invasion and frequency of lightning disasters.
2. work status indication is convenient for observing
work condition.
3. equipped with high voltage DC fuse and circuit
breaker, two level safety protection device.
4. it can be configured according to the needs of
sensors and monitoring and display module to measure and monitor
the current of each road, and can record and display the running
condition remotely, without the scene (selection).
Product specification
Model | RTS3-C40 | |||
Rated Operating Voitage | UC | 500 | 800 | 1000 |
Voltage protective level | Up(KV)≤ | 1.8 | 3.0 | 3.6 |
Max discharge current | Imax(8/20μS) | 40 | ||
Nominal discharge current
| In(8/20μS) | 20 | ||
Ressponse time | NS | <25 | ||
Lndication of invalidation | Aging invalidation:green Normal,red:Invaldation | |||
Operating condition | Temp:-40℃~+70℃ | |||
RH≤95%(25℃) | ||||
Sea level elevation≤3km | ||||
Remote signal function
| Can also picking | |||
Remarks | Other max continuous operating voltage can be customized |
Use of attention
1. in order to avoid unnecessary induction loops, we should
mark the PE conductor of each device.
2. device and the SPD set up the equipotential connection.
3. the energy coordination of multilevel SPD
4. the connection requirements of more than 2.5mm2;
when the length of more than 0.5 meters of more than 4mm2
Company profile
Thor has been designing new products to meet the RoHS
directive since 2006. Thor’s ongoing commitment to RoHS compliance
includes continuing efforts to reduce the presence of hazardous
substances in the design and manufacture of a growing number of
popular products.
Ltd is committed to meeting the requirements of the
European Union’s Waste Electrical and Electronic Equipment (WEEE)
directive. This directive requires producers of electrical and
electronic equipment to finance the take-back for re-use or
recycling of their products placed on the EU market after 2005.