Zhejiang THOR Electric Co., Ltd |
|
TNC interface type antenna signal lightning arrester outdoor antenna lightning surge protection
Brief introduction
The TNC interface lightning protector is a design of
lightning protection applied to the antenna feeder system based on
the relevant standards. It is applied to communication station,
radar station, PHS base station, mobile communication base station,
GPS base station, CDMA base station, PHS (PAS) base station,
satellite communication, microwave station and so on. It has high
effective defense function for lightning high voltage pulse induced
on the feeder line, which can prevent the antenna and transceiver
caused by the feeder line induced lightning overvoltage. Damage.
Product specification
Model and specofocation | TRSW-BNC | ||||||
Frequency range | DC-1.5 GHz | ||||||
Working voltage | 500V | ||||||
Nominal discharge current | In(8/20μS) | 10kA | |||||
Insulation resistance | ≥5000 MΩ | ||||||
Dielectric withstanding voltage | 1500V | ||||||
Impedance | 75Ω | ||||||
Interface mode | BNC.N.UHF.TNC and so on | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remarks | Other max continuous operating voltage can be customized |
Working principle of product
The lightning protection device is based on the
principle of standing wave antenna and lightning wave spectrum
design. The main part is a short rod equivalent to the end of the
1/4 wavelength. When the signal is sent out, a part of the
impedance is reflected back because the impedance is not fully
matched, and the wave will form a standing wave when the wave is
superimposed on the incident wave originally emitted. The amplitude
of standing wave at each point of the line is fixed first. For the
transmission line with terminal short circuit, the terminal is
short circuited, so the current is large and the voltage is small.
For the signal end, the voltage and the current are small.
That is, the most close to the open circuit of the
signal terminal impedance, so the loss is small, but for the
lightning wave because of its wide spectrum range, and most of the
energy is concentrated in the frequency band below 10HZ, so the
short circuit rod is short circuited to the lightning, and will not
invade the equipment to cause damage.
Product features
1. resistance to impact and corrosion resistance
2. the solid and conductive metal shell has a good shielding
effect, so that the signal is free from external interference.
3. core components are strictly screened, and brand products
are selected for superior performance.
Use of attention
1. grounding lines should be short, thick and straight,
so as to reduce the influence of distributed inductors on the
ability of lightning electromagnetic pulse.
2. please recognize the interface and the way of connection
3. the wire on the lightning arrester is welded to the
shortest grounding wire (the wire area is not less than 2.5mm2),
the other end is connected to the grounding bus of the lightning
protection system, and the grounding resistance is not more than 4
Omega.
4. the product is TNC type interface, which is not
suitable for other interfaces.
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport