Zhejiang THOR Electric Co., Ltd |
|
household outdoor copper lightning arrester, stainless steel lightning rod, grounding bar.
Brief introduction
the lightning rod is the lightning protection measures
adopted by Zhejiang tohr Electric Co., Ltd. to independently
develop and produce lightning strike hazards. The main material is
304 stainless steel. It is resistant to rust and beautiful
appearance. The needle tip is made of special metal. It has strong
resistance to flash and solubility, safety and reliability of
mechanical connection, beautiful design of flange, convenient and
quick installation.
Product specification
Model | Specifications | With flange height M | Texture of material | working temperature |
TRSB
| 3.1 | 1.2
1.5
1.8
The highest 20m can be done |
Stainless steel
|
-40℃ ~ +80℃
|
3.3 | ||||
4.3 | ||||
5.3 | ||||
6. |
Working principle of product
when the thunder discharge close to the ground when it makes the
ground electric field distortion. At the top of the lightning rod,
the space of the local electric field is formed to influence the
direction of the development of the lightning pilot discharge,
guiding the lightning to discharge to the lightning rod, and
introducing the lightning current through the grounding wire and
grounding device to the earth, so that the protected object will
not be struck by lightning.
Product features
1. beautiful and decorative
2. under the same condition (height), the protection range
is larger than the ordinary lightning rod.
3. safe and reliable: no radioactive elements, stainless
steel, corrosion resistance and strong wind resistance.
Use of attention
1. the distance between the independent lightning rod
and the protected object should be no less than 5m, so as to avoid
the counterattack when lightning strikes the lightning rod. The
independent lightning rod shall be equipped with an independent
grounding device, and the distance between the grounding conductor
and the grounding wire shall not be less than 3m.
2. No lightning rod should be installed on the portal frame
of the pressure device.
3. it is strictly prohibited to install overhead
lighting lines, telephone lines, broadcasting lines, antennas, etc.
on lightning rods or frames.
Company profile
Thor is all about protecting against the damaging effects of
power transients. It is our goal and mission to connect our
customer challenges with high-quality, right-priced solutions and
products – completed by unrivaled customer service and technical
support.
following the international quality system standards, is ISO
9001 certified and our technical standards are in line with
GB18802.1-2011/IEC61643-1.