Zhejiang THOR Electric Co., Ltd |
|
BNC home lightning protection protector, control signal, lightning protector, surge protector.
Product introduction
The control signal lightning protector is a lightning
protection measure adopted by Zhejiang tol Electric Co., Ltd.,
which is independently developed and manufactured for signal
circuit protection. The control signal lightning arrester is mainly
used to protect the lightning (overvoltage) along the low voltage
control signal circuit, so as to protect all kinds of voltage
connected control signal equipment which are sensitive to
electromagnetic interference.
Product features
1. the low attenuation and return loss in the wide
frequency range ensure that the lightning arrester does not affect
the system performance.
2. core components are strictly screened and their
performance is superior.
3. low insertion loss to ensure unblocked lines
Use attention,
1. temperature: -40 to 70 DEG C; relative humidity: less
than 95%; atmospheric pressure: 70kPa ~ 106 kPa.
2. Connect the protector to the front end of the protected
device, so it must be connected reliably.
3. the lightning arrester is not required for long
maintenance without longer maintenance. It only needs to be
maintained by the system. In the course of use, the signal
transmission is problem and the signal transmission is restored to
normal after the surge protector is replaced, indicating that the
surge protector has been damaged and needs to be repaired or
replaced.
Product specification
Model and specofocation | TRSS-BNC | ||||||
Working voltage | 24V | ||||||
Max continuous operating voltage | Uc | 30V | |||||
Voltage protective level | Up(V)〈 | 〈60 | |||||
Nominal discharge current | In(8/20μS) | 10kA | |||||
Response time | ns | ≤10 | |||||
Characteristic impedance | 75Ω | ||||||
Insertion loss | ≤0.1dB | ||||||
Configuration dimension | 52×25×25 | ||||||
Interface mode | BNC | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remarks | Other max continuous operating voltage can be customized |
Working principle of product
The control signal surge protector is connected to the front end of
the protected equipment. When the transmission line is impacted by
the inductive thunder and other transient overvoltage, the impact
current is discharged to the earth through the protection branch of
the surge protector, and the output voltage is placed in the
allowable voltage range of the equipment, thus ensuring the safety
of the operating equipment.
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport