Industrial RS485 signal protector, control signal, surge protector, arrester 5V12V24V.
Product Details
The control signal lightning arrester is a lightning protection
measure developed by Zhejiang tohr Electric Co., Ltd., which is
independently developed for signal circuit protection. The control
signal lightning arrester is mainly used for lightning
(overvoltage) protection along the low voltage control signal
circuit, which is widely used in the financial system,
telecommunication system, transportation system, petrochemical
industrial control system, such as various data transmission lines,
monitoring and control lines, instrument signal lines and so on.
Product specification
Model and specofocation | TRSS-485 | ||||
Rated Operating Voltage(V) | Un | DC6 | DC12 | DC24 | DC48 |
Max continuous operating voltage(V) | Uc | DC9 | DC18 | DC36 | DC75 |
Voltage protective level(V) | Up〈 | 〈12 | 〈30 | 〈60 | 〈120 |
Nominal discharge current | In(8/20μS) | 5kA | |||
Max discharge current | Imax(8/20μS) | 10kA | |||
Response time | ns | 1 | |||
Operating condition | Temp:-40℃~+70℃ | ||||
RH≤95%(25℃) | |||||
Sea level elevation≤3km | |||||
Remarks | Other max continuous operating voltage can be customized |
Working principle of product
The control signal surge protector is connected to the front
end of the protected equipment. When the transmission line is
impacted by the inductive thunder and other transient overvoltage,
the impact current is discharged to the earth through the
protection branch of the surge protector, and the output voltage is
placed in the allowable voltage range of the equipment, thus
ensuring the safety of the operating equipment.
Product features
1. core components are strictly screened and their performance is superior.
2. Design of low capacitance and inductance and superior
transmission performance
3. it has self recovery function and provides multiple
protection under lightning prone environment.
Use of attention
1. identify the input / output interface identifier of the
lightning protector, input the external line and output the device.
2. grounding lines should be short, thick and straight,
so as to reduce the influence of distributed inductors on the
ability of lightning electromagnetic pulse.
3. the grounding of industrial control signal lightning
arrester should be connected to the grounding grid through
electronic switches.
Company profile
Thor is following the international quality system standards, is ISO 9001 certified and our technical standards are in line with GB18802.1-2011/IEC61643-1.