Since people now have higher requirements for living environment, and some factories have higher requirements for the production environment, this time requires dust removal equipment to carry out dust removal. Now there are many dust removals equipment, such as the current bag filter, can truly become a device that people will know and is required in many occupations.
Nowadays, such bag-type dust removal equipment can play a good role in dust removal, still due to this equipment, the main is the pulse jet valve used to carry out the dust removal, and then through the dust bag to complete the current dust filtration, reached a good dust removal effect. BRANDO is a professional manufacturer and exporter of dust collector pulse jet valves. Our CA35T diaphragm valves are sold overseas and are well praised. We provide not only quality products, but also professional technical consulting services.
Technical data of Right Angle Pulse Jet Valves:
Model No | CA15T | CA20T | CA25T | CA35T | CA45T | CA50T | CA62T | CA76T |
Nonimal size | φ15 | φ20 | φ25 | φ35 | φ45 | φ50 | φ62 | φ76 |
Port Size | G1/2'' | G3/4'' | G1'' | G1 1/4'' | G1 1/2'' | G2'' | G2 1/2'' | G3'' |
Working pressure | 0.3 to 0.8MPa | |||||||
Temp. range | -5℃ to 55℃ | |||||||
Relative humidity | ≤85% | |||||||
Working medium | Compressed clean air | |||||||
Voltage | 24VDC, 220VAC |
Dimension of CA35T Goyen Type Pulse Jet Valve:
Video of CA35T Goyen Type Pulse Jet Valve:
Detail images of Goyen Type Pulse Jet Valves:
More Goyen Type Pulse Valve For You to Choose:
Threaded Type Immersion Type Dresser Nut Type Flanged Type
RCA Series Solenoid Coil Armature Assembly Pulse Controller
Installation:
1. Prepare supply and blowtube pipes to suit valve specification.
Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other
particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no
excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot
port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation
leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.