6011 6012 Plunger Solenoid Valve BD-C DIN43650B Electrical Coil

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

6011 6012 Plunger Solenoid Valve BD-C DIN43650B Electrical Coil

 

This solenoid valve coil is suitable for the type 6012 plunger 3/2 way solenoid valve. A solenoid valve is a device that is used to cut off the circulation of water, oil, gas, and the like. Solenoid valves are commonly used in our daily chemical equipment pipelines, such as water plants, steam pipes, chemical equipment, but because of the different lengths of use of each substance, we are divided into normally open and normally closed solenoid valves. We choose to use the normally open solenoid valve or the normally closed solenoid valve difference and suggestion: the solenoid valve is divided into two types: normally closed type and normally open type: 1. Normally closed type means that the line is broken when the coil is not energized. 2. Normally open type means that the pipeline is open when the coil is not energized.

 

Technical parameter of 6011 / 6012 Type Solenoid Valve Coils:

Model numberBB08029101
Normal voltageDC24V, AC110V, AC220V (±10%) (Other can be customized)
Normal powerAC:5VA
MaterialPlastic, Brass
Wire classH, F
ConnectionDIN 43650B
ApplicationType 6011 / 6012 Plunger Valve 3/2 Way Direct Acting
Hole diameter8 mm
Height29 mm
Width19.6 mm

 

Main dimension of 6011 / 6012 Type Plunger Valve Solenoid Coil:

 

DIN 43650B connection of 6012 Type Electric Magnetic Coils:

 

Production of  Type 6012 / 6011 Plunger Valve Electromagnetic Coil:

 

More details about 6012 / 6011 Type Solenoid Valve Coil AC220V For Plunger Valve in below Youtube Video:


 

The five main reasons why the solenoid valve does not work, have you encountered it?

In the common problems of solenoid valves, the problems that can not work normally after power-on are very common. So what is the problem? The following 5 reasons are for your reference:


1. The fluid pressure or the pressure difference of the task does not match. This will cause the solenoid valve to fail to work properly. The medium cannot pass. The working conditions of the solenoid valve cannot meet the practical working requirements and are not within the scope of the practical working environment.


Disposal method: Adjust the pressure or working pressure difference or change the appropriate product.


2. The valve core and the moving iron core are mixed with impurities and impurities. When the impurities enter the outside of the solenoid valve, the solenoid valve products will not work properly.


Disposal method: Stop the cleaning on the outside and install the filter valve before the valve.


3. Fluid viscosity or temperature does not fit, this is generally due to the wrong choice of the solenoid valve product model, perhaps the property of the media has changed.


Disposal method: Check the properties of the media, you can adjust the media properties to stop the adjustment, otherwise you need to change the appropriate products.


4. Before the valve filter or pilot valve hole infarction, this is also caused by too much impurities.


Disposal method: Invert the filter and pilot valve hole of the solenoid valve, and clean the filter or pilot valve hole. In addition, the medium reflecting the solenoid valve is required. Excessive impurities should be stopped in time.


5. When the task frequency is too high or the life is expired, the task frequency of too high will affect the normal operation of the solenoid valve. In addition, if the working time of the solenoid valve is too long and the life is expired, the solenoid valve will not work normally.


Disposal method: Reorganize the product model or change the new product. If the wrong operation and maintenance, maintenance and maintenance, will lead to the solenoid valve can not be used properly.

 

Welcome to your any question and inquiry!

Hot Products

300 bar High Pressure Stainless Steel Water Air Solenoid Valve 220V 110V 24V 12V Product Features: 1...
140 bar Stainless Steel High Pressure Solenoid Valve For Water Air 24V 110V 220V Product Features: 1...
120 bar High Pressure Stainless Steel Solenoid Valve For Water Air 24VDC 220VAC Product Features: 1. ...
8mm Hole Diameter EVI 7/8 DIN43650B Pneumatic Solenoid Valve Coil EVI 7/8 AMP 6.3 x 0.8 AMISCO Type ...
6011 6012 Plunger Solenoid Valve BD-C DIN43650B Electrical Coil This solenoid valve coil is suitable ...
Water Purifier Reverse Osmosis System Water Solenoid Valve Coil The RO water solenoid coil is ...