LOVATO Type DC12V 11W LPG CNG Multivalve Valve Solenoid Coil

 

The solenoid valve of the car includes a solenoid valve coil, which occupies this important position in the entire device, and the coil device as a whole cannot work. The development of automotive solenoid valves is relatively late, the main reason is the problem of coils. People have applied electromagnetic properties earlier, but when they started to study the coils suitable for solenoid valves, they could not find a suitable coil to carry out the work of energization.

 

Now with the continuous development of technology, automotive solenoid valves are also constantly developing. In order to make the development of automotive solenoid valves faster, the first is the development of solenoid valve coils. Only the technical development of this coil can better promote the development of automotive solenoid valves. The operation of this equipment is relatively simple, and it can work directly by directly energizing the side.

 

Technical parameter of Lovato Type LPG Reducer Solenoid Valve Coils:

Model numberBB13336518
Normal voltageDC12V (Other can be customized)
Normal powerDC:17W
Insulation classH
Connection typeDEUTCH
Application

RGJ/RME LovatoType LPG Reducer Repair Kit

MVAT3579/MVAT3755 Tomasetto Lpg Reducer Accessories

Weight122.5 g
Hole size13 mm
Height36.5 mm
Width32 mm

 

Temperature rise and maximum temperature requirements of solenoid coil:

Insulation classMaximum normal temperature rise (℃)Maximum temperature(℃)
B90130
F115155
H140180
N160200
R180220
Tips: Not applicable to pulsating operating coils!

 

Main dimension of RGJ/RME Autogas Reducer Repair Kit Electric Magnetic Coils:

 

Physical map of LPG MVAT3579/MVAT3755 Tomasetto reducer electromagnetic coils:

 

Application of DC12V LPG Autogas Reducer Conversion Kit Solenoid Coil:

 

More details about Lovato type RGJ / RME reducer solenoid coils can be found below the Youtube video:


 

Notes on the use of solenoid valve coil:
1. When the coil is energized, it is strictly forbidden to cover to prevent overheating and burning;


2, electromagnetic coil, socket, electromagnet and connecting parts, it is strictly prohibited to hit the collision to avoid damage;


3. When the coil is energized for normal operation, due to its own heat, the temperature is high, please do not touch it;


4. The working pressure, temperature and viscosity of the medium shall not exceed the specified range;


5. The actual power supply voltage must not exceed the specified range;


6. Ordinary solenoid valve coils should not be used in explosive places;


7. The internal parts of the solenoid valve and the filtering device must be cleaned regularly;


8. Check the model and parameters on the valve label, which must meet the technical requirements of the site;


9. Check the coil, electromagnet and electrical socket to ensure no external damage;


10. When the solenoid valve coil is not used for a while, it can be stored in the room where 0 °C - 40 °C, relative humidity <80%, and no corrosive gas, no open storage is allowed;


11. When the electromagnetic valve is installed in the open air, a protective cover must be installed to ensure performance and extend the service life;


12, AC solenoid valve coils must not be energized with no load, otherwise there is a danger of burning;


13. The best installation method of the solenoid valve is perpendicular to the horizontal pipe, the coil is upward, and the maximum inclination angle is <30° during installation. Otherwise, normal use cannot be guaranteed;


14. Clean and purify the pipeline. The working medium of the solenoid valve should be clean. If the medium contains particulate impurities, a filter device must be installed on the pipeline before the valve;


15. Connect the valve's interface to the pipe according to the direction indicated by the arrow on the valve body, and ensure that the joint is well sealed.

 

Welcome to your inqiuiry!

Hot Products

Atk09.BC11.0030 DC12V 11W LPG CNG System Green Solenoid Valve Coil Solenoid coils play a key role in ...
03.065.122 12V 11W Petrol LPG Gasonline Electrovalve Magnetic Coil Solenoid coils play a key role in ...
ATIKER Type Art09.BC08.0010 8W 12V DC Red Solenoid Valve Coil The Gas cut-off solenoid coil is an ...
Art09.BC08.0020 8W 12V DC Blue Multivalves Reducer Solenoid Valve Coil The Gas cut-off solenoid coil ...
LOVATO Type DC12V 11W LPG CNG Multivalve Valve Solenoid Coil The solenoid valve of the car includes ...
TOMASETTO Type MVAT3579 118151001 DC12V 11W Petrol Solenoid Valve Coil The solenoid valve of the car ...