Home Companies Ningbo Brando Hardware Co., Ltd

EVR Series BG380AS 018F6803 Solenoid Valve Coil In Refrigeration System

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

EVR Series BG380AS 018F6803 Solenoid Valve Coil In Refrigeration System

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

EVR Series BG380AS 018F6803 Solenoid Valve Coil In Refrigeration System

The most common material for solenoid coil thermosetting is BMC material, which is a material with high temperature resistance and water repellency preference and has good high pressure resistance. The most common solenoid material for solenoid coil is PA66 glass fiber-containing material. The speed is fast, and the cost will be lower than that of BMC. Our solenoid valve coils are protected to IP65.

 

As long as there is current (whether AC or DC) flowing in the coil, the coil will heat up. This is a physical phenomenon. If there is only a voltage (electromotive force) at both ends of the coil, there is no current, the wire will not heat up; the degree of heating of the coil and the wire The cross section, the height of the voltage, the magnitude of the current, the frequency of the alternating current, and the size of the core are closely related.

 

Technical parameter of Copper refrigeration solenoid valve coils:

Model NumberBB15045054
Normal voltageAC220V; DC24V; or OEM
Normal powerAC:25VA DC16W
Insulation classH
Connection typeDIN43650A
ApplicationEVR refrigeration solenoid valve series
Net Weight487.5 g

 

Main dimension of 15 mm hole diameter of refrigeration electromagnetic valve coils:

 

Three type EVR refirgeration solenoid valve series acessories for you to choose:

 

Factory display of AC220V/DC24V refrigeration system solneoid valve coils:

 

The main purpose of automation is to optimize the performance of the refrigeration system, including:

• Use an expansion valve to control the injection of liquid refrigerant into the evaporator.

 

• Use the accumulator to compensate for changes in the level of the condenser.

 

• Use a solenoid valve with coils to control the flow of liquid to the evaporator.

 

• Protect the system with a safety device to prevent pressure from being too low or too high.

 

• Use oil separators to minimize oil entry into the system.

 

• Use a dry filter to prevent damage from moisture and contaminants in the system.

 

• Use a sight glass to prevent excess or insufficient refrigerant in the system and check the refrigerant condition.

 

• Minimize repair time with shut-off valves or ball valves.

 

• Use a pressure regulator to maintain system temperature and pressure at the low and high pressure ends.

 

• Increase system efficiency with expansion valves, oil separators, and condensing pressure controllers.

 

Main parts and accessories for automated refrigeration systems:

1. The copper tube is a capillary tube and acts as a throttling;
2. The solenoid valve acts as a control flow no matter where it is. The on/off of the coil determines the switch of the solenoid valve.

 

The vapor compression refrigeration system consists of the following components to form a closed system. The system is filled with refrigerant, which is driven by the compressor to circulate in the system pipeline, and absorbs heat through the evaporator and the condenser to release heat to achieve the cooling function.


(1) Compressor: The compressor used in the conventional refrigerator is a reciprocating piston type totally enclosed compressor;


(2) Condenser: The condenser of the refrigerator is cooled by natural convection by air, and the refrigerant vapor is condensed into a liquid, and the condensers are respectively placed inside the tank walls on both sides of the refrigerator cabinet.


(3) Evaporator: The evaporator is a component in which the refrigerant evaporates to produce a cooling effect, and has a refrigerating compartment evaporator and a freezer compartment evaporator. The refrigerator compartment evaporator is attached to the foam layer side of the rear wall of the refrigerator compartment, and the freezer compartment evaporator is directly fixed in the freezer compartment tank.


(4) Capillary: The capillary is an elongated copper tube that acts as a throttling mechanism in the refrigeration system.


(5) Drying filter: It is placed between the condenser and the capillary to absorb moisture.

 

Welcome to your inquiry!

Hot Products

Fast Twist Pneumatic Hose Fitting Male Banjo 1/8'' 1/4'' 3/8'' 1/2'' BRANDO - Specialist in CNC ...
14.5mm Hole Type 6013 6014 5404 Plunger Solenoid Valve Magnetic Coil What problems occur when the ...
MD01-25 MD02-25 MD01-25M Diaphragm For Taeha Pulse Jet Valve MD01-25, MD02-25, MD01-25M Diaphragm ...
EVR Series BG380AS 018F6803 Solenoid Valve Coil In Refrigeration System The most common material for ...
Membrane For JOIL Pulse Jet Solenoid Valve JISI80 JISR80 JIHI80 JIHR80 Ordering Code of Diaphragm ...
CKD Type AB410 Waterproof Solenoid valve Replacement Magnetic Coil This solenoid valve coil is ...