1070/4 1/2'' Inch SAE Flare Castel Type Refrigeration Solenoid Valve

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

1070/4 1/2'' Inch SAE Flare Castel Type Refrigeration Solenoid Valve

 

1070/4S: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil.

1070/4A6: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil.

1070/4A7: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil.

HF2 HF3 HM2 HM3 HM4 CM2 Coil can be mounted on the valve.

 

Technical Data:

 

Operating Principles
Model Number
SAE Port
Seat size nominal Ø [mm]
Kv Factor
[m3/h]
PS
[bar]
TS[℃]
TA[℃]
min
max
min
max
Direct Acting
1020/2
1/4''
2, 5
0, 175
45
-35
+110
-35
+50
1020/3
3/8''
3
0, 23
Diaphragm Pilot Operated
1064/3
3/8''
6, 5
0, 80
45
-35
+105
-35
+50
1064/4
1/2''
1070/4
1/2''
12, 5
2, 20
1070/5
5/8''
2, 61
1090/5
5/8''
16, 5
3, 80
1090/6
3/4''
4, 80
Piston Pilot Operated
1034/3
3/8''
6, 5
1, 00
45
-35
+110
-35
+50
1034/4
1/2''
1040/4
1/2''
12, 5
2, 40
1040/5
5/8''
3, 00
1050/5
5/8''
16, 5
3, 80
1050/6
3/4''
4, 80

 

Dimension:

 

Replacement Castel Type Solenoid Coil:

 

  

Before Installation:
Before connecting the valve to the pipe, it is advisable to make sure that the refrigerating system is clean. In fact, valves with P.T.F.E. gaskets, and particularly piston valves, are sensitive to dirt and debris.

Furthermore, check that the flow direction in the pipe corresponds to the arrow stamped on the valve body. All the valves can be mounted in any position so long as the coil does not point downwards.

The brazing of valves with solder connections should be carried out with care, using a low melting point filler material. It is not necessary to disassemble the valves before brazing, but it is important to avoid direct contact between the torch flame and the valve body, which could be damaged and compromise the proper functioning of the valve.

Before connecting a valve to the electrical system, be sure that the line voltage and frequency correspond to the values marked on the coil.

 

Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Hot Products

1020/2S 1/4'' Direct Acting SAE Flare NC Refrigeration Solenoid Valve 1020/2S: 1/4'' Direct Acting ...
24V DC Solenoid Coil For Scania Truck Solenoid Valve 1536305 1421325 This is 24VDC 10W solenoid coil ...
1064/3 3/8'' Inch SAE Flare Castel Refrigeration Solenoid Valve 1064/3S: 3/8'' Diaphragm Pilot ...
1068/3 Diaphragm Pilot Operated ODS 3/8'' Cooling Solenoid Valve 1068/3S: 3/8'' Inch Diaphragm Pilot ...
1070/4 1/2'' Inch SAE Flare Castel Type Refrigeration Solenoid Valve 1070/4S: 1/2'' Inch SAE ...
Castel Type 1078/4 1/2'' Inch ODS Connection HM2 Solenoid Valve 1078/4S: 1/2'' Inch ODS Connection ...