Ningbo Brando Hardware Co., Ltd |
Verified Suppliers
|
|
CA50MM 2'' Inch Submerged Goyen Type Dust Collector Pulse Jet Valve
Installation:
1. MM valves are installed through the tank;
2. To avoid any potential operational problems it is preferable
that the valves are not mounted underneath the tank where
condensation may collect. All O-rings should be coated with a
siliconebased lubricant or similar.
3. Dresser nut seals where used are a pressure seal only, not a
structural component. Do not rely on dresser seals to retain either
the tanks or blowtubes. Tanks and blowtubes must be independently
restrained.
4. Tighten dresser nuts to 20 Nm (15 ftlbs) max.
5. Tighten pipe outlets to 20 Nm (15 ftlbs).
6. Make electrical connections to solenoid or connect RCA pilot
port to pilot valve (RCA valves only).
7. Ensure compressed-air supply is dry and free from oil and dirt.
8. Check all cleaning system components are secure before applying
pressure.
9. Apply moderate pressure and check for leaks.
10. Fully pressurise system.
11. Test fire and listen for proper actuation and crisp pulse
noises.
Technical Data of Goyen Pulse Jet Valve:
Model No | CA25MM | CA40MM | CA50MM | CA62MM | CA76MM | CA102MM | ||
Nominal Size | 25 | 40 | 50 | 62 | 76 | 102 | ||
Port Size | mm | 25 | 40 | 50 | 62 | 76 | 102 | |
inch | 1'' | 1 1/2'' | 2'' | 2 1/2'' | 3'' | 3 1/2'' | 4'' | |
Pressure Range | 0.3 to 0.8MPa | |||||||
Temp. Range | Nitrile seals | -40 to 82℃ | ||||||
Viton seals | -29 to 232℃ |
Main Dimension:
CA RCA Series Pulse Jet Valve For Dust Collector System:
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!