Ningbo Brando Hardware Co., Ltd |
Verified Suppliers
|
|
Goyen Type Pulse Jet Valve CA25DD010 CA25DD010-300 CA25DD010-305
This is CA25DD Goyen Type Dresser Nut Pulse Jet Valve; Reference No: CA25DD000, CA25DD001, CA25DD010, CA25DD000-300, CA25DD001-300, CA25DD010-300, CA25DD000-305, CA25DD001-305, CA25DD010-305, CA25DD000-331, CA25DD001-331, CA25DD010-331. Dresser Nut port connection; NBR diaphragm; 24V DC, 220V AC (50/60Hz) voltages for you to choose; other voltages can be customized.
Installation:
1. Prepare supply and blowtube pipes to suit valve specification.
Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other
particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no
excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot
port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation
leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.
Dimension of CA25DD Goyen Type Pulse Jet Valve:
Video of CA25DD Goyen Type Pulse Jet Valve:
Technical data of Dresser Nut Pulse Jet Valves:
More Goyen Type Pulse Valve For You to Choose:
Threaded Type Immersion Type Dresser Nut Type Flanged Type
RCA Series Solenoid Coil Armature Assembly Pulse Controller
Working Principles:
The electromagnetic pulse valve is composed of electromagnetic pilot operator, diaphragm and valve body. Due to difference of pressure acting on two sides of the diaphragm, the diaphragm is pressed closely against the outlet of valve to keep the valve stays in “closed” position.
When energized by an electric signal from the controller, the electromagnetic armature will move to open the discharge opening of back cavity.
The compressed air in back cavity bursts out to relief pressure and pressurized air in front cavity pushes up the diaphragm to open the main outlet of valve, then the electromagnetic pulse valve opens and starts to blow.
When the signal disappears and the spring works immediately to send the pilot operator back to its original position and close the discharging opening. The diaphragm will close the passage by the effect of the pressure in the front cavity and the spring. The pulse valve stops blowing.
The orifice in the diaphragm damps the airflow when the armature is lifting up for releasing the pressure. When the discharge hole closed, the pressure gas will fill into the front cavity to close the passage by the diaphragm. The pulse valve stops blowing.