Home Companies Ningbo Brando Hardware Co., Ltd

Lead Wire Solenoid Coil AC220V 5VA DC24V 2.8Watt For 4V110 Pneumatic Valve

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Lead Wire Solenoid Coil AC220V 5VA DC24V 2.8Watt For 4V110 Pneumatic Valve

Country/Region china
City & Province ningbo zhejiang
Categories Solar Chargers
InquireNow

Product Details

Lead Wire Solenoid Coil AC220V 5VA DC24V 2.8Watt For 4V110 Pneumatic Valve ​

Applicable Industries:Solenoid Valve
Type:Fittings
Place of Origin:Zhejiang, China
Brand Name:Brando
Hole Size:8.0mm
Height:23.5mm
Width:17.5mm
Voltage:AC220V, DC24V
Power:5VA, 2.8W
Connection Type:Lead wire
Insulation class:F, H
Protection class:IP65, IP67, IP68
Application:4V110 pneumatic valve

 

Standard coils are available for insulation classes E, F and H. The insulation class determines the coil’s maximum operating temperature for a specific life:
-Class F: 20 000 hours
-Class H: 30 000 hours

Class F coils are rated to 155℃, basically the copper wire windings can withstand a working temperature up to but not exceeding 155℃. This are the most common form of solenoid coil and are ideally suited to working ambient temperatures up to 20 ℃ and media up to 100℃.

 

Class H coils are rated to 180℃, basically the copper wire windings can withstand a working temperature up to but not exceeding 180C. This are the most common form of solenoid coil and are ideally suited to working ambient temperatures up to 50 ℃ and media up to 180℃.

 

Class N coils are rated to 200℃, basically the copper wire windings can withstand a working temperature up to but not exceeding 200℃. This are the most common form of solenoid coil and are ideally suited to working ambient temperatures up to 80 C and media up to 200℃.

 

Dimension of 4V110 series pneumatic valve Solenoid Coil :

Dimension of 4V110 series pneumatic valve Solenoid Coil :

Technical Data:
 

Model
BB08023502
Hole size
8.0mm
Height
23.5mm
Width
17.5mm
Voltages
AC220V, DC24V
Power
5VA, 2.8W
Insulation class
F, H
Connection Type
Lead wire
Application examples
4V110 series pneumatic valve
 

 

Attention:

1. This air suspension compressor pump solenoid coil is made of high quality components.
2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Hot Products

DC10V DC12V 2Ohm 2.8Ohm 3Ohm Taxi BRC 4 Cylinder LPG CNG Fuel Injector Rail Repair Kit Solenoid Coil ...
Lead Wire Solenoid Coil AC220V 5VA DC24V 2.8Watt For 4V110 Pneumatic Valve ​ Applicable Industries...
DIN43650C 12VDC 24VDC 110VAC 220VAC Solenoid Coil For Pneumatic Valve​ Applicable Industries...
AMP 6.3 x 0.8 EVI 7/8 Solenoid Coil For Pneumatic Solenoid Valve Applicable Industries:Solenoid ...
Bosch Rexroth Type Hydraulic Solenoid Coil 12VDC 24VDC R900021389 R901370939 This is hydraulic ...
RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil Applicable Industries...