Home Companies Ningbo Brando Hardware Co., Ltd

Multivalve E08G LPG Electrovalve RGJ R03 CNG Reducer Kit Solenoid Coil

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Multivalve E08G LPG Electrovalve RGJ R03 CNG Reducer Kit Solenoid Coil

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

Multivalve E08G LPG Electrovalve RGJ R03 CNG Reducer Kit Solenoid Coil

 

Product Features:
1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.

 

What problems occur when the solenoid valve coil is in use?

Everyone knows that solenoid valves play an important role in industrial applications, and they have a long running time, and sometimes there are some problems that make the equipment not function properly. Most of this problem is caused by improper use of the solenoid valve coil.

The solenoid valve coil may not be very secure at the time of installation. During the operation of the device, the coil is in a strong operation, so that the coil will fall, the solenoid valve will not operate normally, or some may fall, and some may not. It may cause the device to work for a while and not work properly, both of which will delay the work. At this time, the operation is relatively simple, and the coil can be firmly fixed on the solenoid valve. There is also a case where the solenoid valve coil may be burnt out due to excessive voltage, and the device may not operate normally.

Therefore, when using the solenoid valve later, be sure to check the position of the solenoid valve coil and do the correct operation of the solenoid valve coil. This will ensure that the solenoid valve will not cause problems.

 

Dimension of BB1336518 Solenoid Valve Coil :

Dimension of BB1336518 Solenoid Valve Coil :

Technical Data:

Model
BB13336518
Hole Size
13.3mm
Height
36.5mm
Width
32mm
Connector
AMP
Insulation Class
H
Protection Class
IP65, IP67, IP68
Normal Voltage
DC12V
Power
17Watt
Application
RGJ-3.2L/3.2LDD Reducer, RGJ UHP Evaporator, CNG Reducer RME010


Solenoid Coil Production Line:

 
 

Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.

2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

The life of a solenoid valve coil is determined by its own quality factors, and is also affected by the following factors:


1. Long-term contact with too humid air
If you use the solenoid valve coil to make it contact with very humid air for a long time, it will also have a certain adverse effect on the service life of the coil.


2. The heating problem that occurs during the use of the coil
Although the solenoid valve coil will be in contact with electric power, it will generate heat under normal application conditions, but if it is heated due to various external factors, it will also be used because of this heat. Life is shortened.


3. Poor power usage
If the process of the solenoid valve coil is applied, the process has poor application problems in the power supply, such as excessive voltage supply or excessive current, which may cause certain adverse effects on the life of the coil.
In order to extend the life of the solenoid valve coil, the above undesirable factors should be avoided.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry! 

Hot Products

Dust Collector Pulse Valve Repair Kit Solenoid Coil With Flying Leads The pulse valve includes a ...
Best.Nr.0200 Solenoid Coil For 2636000 2637050 8020865 Solenoid Valve The shown Best-Nr.0200 ...
Membrane For Joil Dust Collector Pulse Solenoid Valve JISI50 JIFI50 JIHI50 This diaphragm is used in ...
DC12V DC24V Automobile Parts 0200 Solenoid Coil With Plug Connector Hole Size:13.2mm Height:40.5mm ...
Multivalve E08G LPG Electrovalve RGJ R03 CNG Reducer Kit Solenoid Coil Product Features: 1. Using ...
Landi Renzo LPG CNG Pressure Reducer Regulator Solenoid CNG Electrical Magnetic Coil Deucth ...