Solenoid Coil For Coffee Espresso Maker Machine Solenoid Valve GDH14024DS

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

Solenoid Coil For Coffee Espresso Maker Machine Solenoid Valve GDH14024DS

 

Product Features:
1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.

 

 

What problems occur when the solenoid valve coil is in use?

Everyone knows that solenoid valves play an important role in industrial applications, and they have a long running time, and sometimes there are some problems that make the equipment not function properly. Most of this problem is caused by improper use of the solenoid valve coil.

The solenoid valve coil may not be very secure at the time of installation. During the operation of the device, the coil is in a strong operation, so that the coil will fall, the solenoid valve will not operate normally, or some may fall, and some may not. It may cause the device to work for a while and not work properly, both of which will delay the work. At this time, the operation is relatively simple, and the coil can be firmly fixed on the solenoid valve. There is also a case where the solenoid valve coil may be burnt out due to excessive voltage, and the device may not operate normally.

Therefore, when using the solenoid valve later, be sure to check the position of the solenoid valve coil and do the correct operation of the solenoid valve coil. This will ensure that the solenoid valve will not cause problems.

 

Dimension of BB13441037 Solenoid Valve Coil :

Dimension of BB13441037 Solenoid Valve Coil :

Technical Data:

 
CODE
POWER(VA)
VOLTAGE
(V)
FREQUENCY
(Hz)
ED
(%)
AMBIENT
TEMPERATURE
Inrush
Holding
GDH14024DS
27
43
24AC
50/60
100
-20℃ +40℃
GDH14110DS
27
43
110AC
50/60
100
-20℃ +40℃
GDH14223DS
27
43
220/230AC
50/60
100
-20℃ +40℃
GDV14024DY
26
43
24AC
50/60
100
-20℃ +60℃
GDV14110AY
23
43
110AC
120AC
50
60
100
-20℃ +60℃
GDY14230AY
27
43
220AC
240AC
50
60
100
-20℃ +60℃
CODE
POWER(W)
VOLTAGE(V)
ED(%)
AMBIENT
TEMPERATURE
GDH14024CS
14
24DC
100
-20℃ +40℃
GDV14024CY
14
24DC
100
-20℃ +60℃


Solenoid Coil Production Line:

 
 

Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.

2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

Troubleshooting of solenoid valve coil failure:

The solenoid valve coil is a relatively common product in magnetic materials. When it is working, there is occasional failure, that is, the solenoid valve does not operate. This kind of fault is a common fault in the use of our daily solenoid valves. Next, we will give you a simple analysis of the troubleshooting method for the solenoid valve coil failure. It should be checked from the following aspects:

1. The solenoid valve terminal is loose or the wire is dropped. The solenoid valve is not energized. At this time, we can tighten the wire. This fault is easier to find.

2. If the solenoid valve coil is burnt out, the wiring of the solenoid valve can be removed, and then measured by a multimeter. If an open circuit occurs, it indicates that the solenoid valve coil is burnt out. The reason is that the coil is damp, causing poor insulation and magnetic leakage, and the current in the coil is too large to be burned, so it is necessary to prevent rainwater from entering the solenoid valve. In addition, the spring is too hard, the reaction force is too large, the number of turns of the coil is too small, and the suction can not cause the coil to burn.

3. The solenoid valve is stuck. The cooperation gap between the sliding valve sleeve and the valve core of the solenoid valve is very small (less than 0.008 mm), and it is generally a one-piece assembly. When mechanical impurities are brought in or the lubricating oil is too small, it is easy to get stuck. The treatment method can use the steel wire to break in from the small hole of the head to make it bounce back. The solution of the foundation is to remove the solenoid valve, take out the valve core and the valve core sleeve, and clean it with CCI4, so that the valve core is sensitive in the valve sleeve. When disassembling, pay attention to the assembly sequence and external wiring orientation of each component, so as to reassemble and wire correctly, and check whether the oil mist injection hole is blocked and the lubricating oil is sufficient.

4. Air leaks. Leakage creates a lack of air pressure, making it difficult to open and close the forcing valve due to damage to the gasket or wear of the spool to create several cavity helium. When dealing with the electromagnetic valve problem of the switching system, it is necessary to select an appropriate opportunity, and then wait for the solenoid valve to be de-energized and then perform corresponding processing. If the processing is not completed within a switching gap, the switching system may be suspended and carefully handled.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry! 

Hot Products

DC12V DC24V Automobile Parts 0200 Solenoid Coil With Plug Connector Hole Size:13.2mm Height:40.5mm ...
Landi Renzo LPG CNG Pressure Reducer Regulator Solenoid CNG Electrical Magnetic Coil Deucth ...
DC24V Solenoid Coil For Truck Parts 0675226 1421323 1340232 1536305 525090 Gearbox solenoid valve ...
Solenoid Coil For Coffee Espresso Maker Machine Solenoid Valve GDH14024DS Product Features: 1. Using ...
BFEC Type Pulse Jet Valve Solenoid Coil For New Version DMF Series Diaphragm Valve AC220V AC110V ...
12VDC 18Watt LPG CNG RGE RGV Reducer Regulator Solenoid Coil Shut Off Valve LPG CNG Repair ...