Solenoid Coil For Coffee Espresso Maker Machine Solenoid Valve GDH14024DS
Product Features:
1. Using high quality wire which has UL approved; 2. Using high
quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and
so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof
coils and so on.
7. If you have special requirement, pls feel free to contact us.
What problems occur when the solenoid valve coil is in use?
Everyone knows that solenoid valves play an important role in
industrial applications, and they have a long running time, and
sometimes there are some problems that make the equipment not
function properly. Most of this problem is caused by improper use
of the solenoid valve coil.
The solenoid valve coil may not be very secure at the time of
installation. During the operation of the device, the coil is in a
strong operation, so that the coil will fall, the solenoid valve
will not operate normally, or some may fall, and some may not. It
may cause the device to work for a while and not work properly,
both of which will delay the work. At this time, the operation is
relatively simple, and the coil can be firmly fixed on the solenoid
valve. There is also a case where the solenoid valve coil may be
burnt out due to excessive voltage, and the device may not operate
normally.
Therefore, when using the solenoid valve later, be sure to check
the position of the solenoid valve coil and do the correct
operation of the solenoid valve coil. This will ensure that the
solenoid valve will not cause problems.
Dimension of BB13441037 Solenoid Valve Coil :
Technical Data:
Solenoid Coil Production Line:
Attention:
1. This air suspension compressor pump solenoid coil is made of
high quality components.
2. Replaces the original air compressor solenoid coil of your car
and equal the original quality.
3. Please double confirm the compatibility as well as the OEM
number before purchasing.
4. Instruction is not included. Professional installation is
recommended.
Steps and methods for properly installing a solenoid valve coil:
1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.
2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.
3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.
4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.
5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.
6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.
7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.
Troubleshooting of solenoid valve coil failure:
The solenoid valve coil is a relatively common product in magnetic
materials. When it is working, there is occasional failure, that
is, the solenoid valve does not operate. This kind of fault is a
common fault in the use of our daily solenoid valves. Next, we will
give you a simple analysis of the troubleshooting method for the
solenoid valve coil failure. It should be checked from the
following aspects:
1. The solenoid valve terminal is loose or the wire is dropped. The solenoid valve is not energized. At this time, we can tighten
the wire. This fault is easier to find.
2. If the solenoid valve coil is burnt out, the wiring of the solenoid valve can be removed, and then measured
by a multimeter. If an open circuit occurs, it indicates that the
solenoid valve coil is burnt out. The reason is that the coil is
damp, causing poor insulation and magnetic leakage, and the current
in the coil is too large to be burned, so it is necessary to
prevent rainwater from entering the solenoid valve. In addition,
the spring is too hard, the reaction force is too large, the number
of turns of the coil is too small, and the suction can not cause
the coil to burn.
3. The solenoid valve is stuck. The cooperation gap between the sliding valve sleeve and the valve
core of the solenoid valve is very small (less than 0.008 mm), and
it is generally a one-piece assembly. When mechanical impurities
are brought in or the lubricating oil is too small, it is easy to
get stuck. The treatment method can use the steel wire to break in
from the small hole of the head to make it bounce back. The
solution of the foundation is to remove the solenoid valve, take
out the valve core and the valve core sleeve, and clean it with
CCI4, so that the valve core is sensitive in the valve sleeve. When
disassembling, pay attention to the assembly sequence and external
wiring orientation of each component, so as to reassemble and wire
correctly, and check whether the oil mist injection hole is blocked
and the lubricating oil is sufficient.
4. Air leaks. Leakage creates a lack of air pressure, making it difficult to
open and close the forcing valve due to damage to the gasket or
wear of the spool to create several cavity helium. When dealing
with the electromagnetic valve problem of the switching system, it
is necessary to select an appropriate opportunity, and then wait
for the solenoid valve to be de-energized and then perform
corresponding processing. If the processing is not completed within
a switching gap, the switching system may be suspended and
carefully handled.