Home Companies Ningbo Brando Hardware Co., Ltd

DC12V 2 Pins Replacement Magnetic Coil For Big Gas LPG CNG Evaporator

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DC12V 2 Pins Replacement Magnetic Coil For Big Gas LPG CNG Evaporator

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

DC12V 2 Pins Magnetic Coil For Big Gas LPG CNG Evaporator ​

 

Deucth connection type solenoid valve coil for auotomobile application, such as car, truch, bus, etc. Normally for CNG LPG pressure reducer application.

Short Description:
solenoid valve coil, magnetic valve coil, solenoid valve importance parts, pilot of solenoid valve

1, Solenoid Coil, Electromagnetic Valve Coil
2, Hole Diameter (aperture) 14.2 mm
3, Height Diameter 34.7mm
3, Normally Used on Solenoid Valve of CNG Application
4, Connection DEUTCH


Detailed Specifications:
Item No.: BB14233016
Normal Voltage: DC12V; Other voltage can be customized
Normal Power: DC13W; Other power can be customized
Insulation Class: H
Connection Type: 6.3x0.8mm
Installation Dimension: Ø14.2XH34.7
Application Example: CNG reducer valve

 

What problems occur when the solenoid valve coil is in use?

Everyone knows that solenoid valves play an important role in industrial applications, and they have a long running time, and sometimes there are some problems that make the equipment not function properly. Most of this problem is caused by improper use of the solenoid valve coil.

The solenoid valve coil may not be very secure at the time of installation. During the operation of the device, the coil is in a strong operation, so that the coil will fall, the solenoid valve will not operate normally, or some may fall, and some may not. It may cause the device to work for a while and not work properly, both of which will delay the work. At this time, the operation is relatively simple, and the coil can be firmly fixed on the solenoid valve. There is also a case where the solenoid valve coil may be burnt out due to excessive voltage, and the device may not operate normally.

Therefore, when using the solenoid valve later, be sure to check the position of the solenoid valve coil and do the correct operation of the solenoid valve coil. This will ensure that the solenoid valve will not cause problems.

 

Dimension of BB14233016 Solenoid Valve Coil :

Dimension of BB14233016 Solenoid Valve Coil :

Technical Data:

Model
BB14233016
Hole Size
14.2mm
Height
34.7mm
Width
32.2mm
Connector
6.3x0.8mm
Insulation Class
H
Protection Class
IP65, IP67, IP68
Normal Voltage
DC12V
Power
13Watt
Application
LPG CNG Multivalves, Evaporator


Solenoid Coil Production Line:

 
 

Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.

2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

Product Features:
1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry! 

Hot Products

DC12V Electrovalve Coil For LPG CNG Pressure Reducer Gas Valve Injector Rail ​ Solenoid coil for ...
Electric Magnetic Solenoid Coil 12V DC For CNG LPG System Pressure Reducer Solenoid Valve ​ ...
01RD00403002 Verdampfer Converter Super Eco AT90E FOX Techno Reducer Regulator Solenoid Coil For LPG ...
AT90E FOX Techno Pressure Reducer Solenoid Coil DC12V With DEUTSCH Connector LPG CNG Repair Kit ​ ...
DC12V 2 Pins Magnetic Coil For Big Gas LPG CNG Evaporator ​ Deucth connection type solenoid valve ...
DC12V LPG CNG Magnetic Coil For C300 Pressure Reducer Regulator With AMP Connector ​ This 10R-30 ...