Ningbo Brando Hardware Co., Ltd |
Verified Suppliers
|
|
AC110V DC12V 3/4'' Inch DN20 DMF-ZM-20 Right Angle Aluminum Alloy Body Control Solenoid Valve
The installment introduction:
1. First, Confirm the pulse valve in good condition and then
installed
2. Pulse valve will be installed directly the outer wall of flange
of gas manifold. The spray pipe across the gas manifold. According
to the drawing and manual, the pulse valve matching appropriate
spray pipe and installation. To avoid the valve install in the air
manifold bottom. If the pulse valve matched trachea and connector,
the connector will be used for sealing purpose only. It can not as
structural support components. It can not rely on the straight
connector fixed spray torch and package. The spray pipe and air
manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten
the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric
control valve seat. Pay attention to the line adown to prevent rain
waterproof. Or through the joint and nylon pipe, it will connect
the pulse valve and electromagnetic assembly boxes of nylon pipe
connection.
5. To ensure that provide compressed air clean and dry. The air
manifold system provides moderate pressure and check for leaks
installation. ( it can brush on soap and water, check whether the
interface is bubble). Pressure was carried out on the air bag
inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa),
recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve
whether it is normal operation and whether the pulse blowing sound
is clear.
Working Principles
The electromagnetic pulse valve is composed of electromagnetic pilot operator, diaphragm and valve body. Due to difference of pressure acting on two sides of the diaphragm, the diaphragm is pressed closely against the outlet of valve to keep the valve stays in “closed” position.
1)When energized by an electric signal from the controller, the electromagnetic armature will move to open the discharge opening of back cavity. The compressed air in back cavity bursts out to relief pressure and pressurized air in front cavity pushes up the diaphragm to open the main outlet of valve, then the electromagnetic pulse valve opens and starts to blow.
2)When the signal disappears and the spring works immediately to
send the pilot operator back to its original position and close the
discharging opening. The diaphragm will close the passage by the
effect of the pressure in the front cavity and the spring. The
pulse valve stops blowing.
3)The orifice in the diaphragm damps the airflow when the armature
is lifting up for releasing the pressure. When the discharge hole
closed, the pressure gas will fill into the front cavity to close
the passage by the diaphragm. The pulse valve stops blowing.
Technical data chart of DMF ZM series solenoid pulse valves in industrial filter use:
Moder Number | DMF-ZM-20 | DMF-ZM-25 | DMF-ZM-40S |
Nominal Size | 20 | 25 | 40 |
Port Size | 3/4 Inch | 1 | 1 1/2 |
Blowing Area(m2) | 3.5~6 | 8~10 | 12~16 |
Number Of Diaphgrams | 1 | 1 | 2 |
KV | 17.55 | 26.16 | 45.82 |
CV | 20.48 | 50.53 | 53.47 |
Pressure | 0.1Mpa~08Mpa | ||
Voltage | AC220V, AC110V, AC24V, DC24V | ||
Temperature | -25℃ to +80℃ |
Dimension Of DMF-ZM-20 fixed nut pulse valve for bag filter
Details About DMF Electromagnetic Valve For Dust Collector
Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly)
Deconstruction Diagram Of DMF-ZM-20
More Details About Pulse Jet Valve On Youtube
Features Of DMF-ZM Series Pulse Jet Valve
1.We Can provide three specifications of valves from 20, 25, and 40S for the selection of pulse bag dust collectors.
2.The valve body and valve cover are densely die-cast, anti-corrosion performance.
3.The gasket on the diaphragm is made of metal and rubber, which has good rigidity and does not leak.
4.The electromagnetic pilot head has a large suction force and is sensitive and reliable.
5.The performance is stable and reliable, and the service life of the diaphragm reaches more than one million times or three years.
Note
A. The inlet and outlet ends of the nozzle and the injection pipe
inserted into the electromagnetic pulse valve should be maintained
at a certain depth. 20 valves is not less than 15 mm.
B. The ZM valve body cannot be used to support and fix the air
distribution box (air bag) and the blowing pipe. Special measures
shall be taken to support and fix it.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!