Home Companies Ningbo Brando Hardware Co., Ltd

M40 1 1/2'' Pneumatic Valve Diaphragm For Industrail Pulse Dust Collector

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

M40 1 1/2'' Pneumatic Valve Diaphragm For Industrail Pulse Dust Collector

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

Pneumatic Power 1 1/2'' TURBO Type Pulse Valve Diaphragm M40

 

TURBO electromagnetic pulse valve diaphragm structure and performance: the performance of nitrile rubber and polysulfur rubber blends used in the diaphragm, the performance of rubber materials used in the canvas disc diaphragm (often called diaphragm), and some silicone rubber, fluoro rubber, chloro rubber diaphragm developed in recent years.

 

Valve body inlet and outlet into a right Angle, directly controlled by electrical signal diaphragm valve; The right Angle electromagnetic pulse valve is the compressed air "switch" of the dust cleaning and blowing system of the pulse bag filter. Controlled by the output signal of pulse jet control instrument, the filter bag is sprayed and cleaned one by one (chamber) to keep the pressure of the dust collector within the set range, so as to ensure the processing capacity and dust removal efficiency of the dust collector.

 

Ordering CodeFitted Valve CodeValve Port SizeMateiral
M25All Type1"Nitrile/Fluororubber
M40FP40,FM40
DP40,DM40
EP40,EM40
1-1/2"Nitrile/Fluororubber
M50FP55,FM55
SQP50,SQM50
SQP60,SQM60
2"Nitrile/Fluororubber
M75FP65,FM65
SQP75-IN,SQM75-IN
SQP100-IN,SQM100-IN
3"Nitrile/Fluororubber

 

Our Diaphragm and Pulse Valve has competitive prices with superior quality

 

 

High working efficiency in bag dust filtration

 

Performance of TURBO Pulse Valve:

TURBO electromagnetic pulse valve diaphragm itself operating temperature range and pressure range depends on the rubber, fabric and structure. The diaphragm can work at -50~100 ° c and 0.4~ 0.8mpa. Fluoro rubber and silicone rubber diaphragm can work at -80~232 ℃. Chlorol rubber diaphragm can work under pressure of 0.4~ 0.8mpa, with good air tightness and aging resistance. A very good emp valve the most important thing is to emp valve diaphragm is good, good coil, these two objects are very important. Magnetic pulse valve be very careful with corrosive or explosive environment requirements corrosion electromagnetic pulse valve or use anti-static solenoid valve, flow temperature is too high, please replace the viscosity of the solenoid valve, when work restricted should choose multi-function solenoid valve, easy to use conveniently, quick maintenance effort, work pressure difference is not appropriate, adjust the differential, or replacement of proportion of electromagnetic pulse valve, according to need to choose model, size of solenoid valve. If the working frequency is too high or the service life has reached, please change the product or update the product. If the liquid viscosity of the filter is too high and the frequency is too high, please consider changing the product. The electromagnetic pulse valve cannot be closed.

 

About Description of Pulse Valve

The service life of emp valve design is generally three years or more than 1 million times, but according to our experience of many years, the number of times of emp valve more than three inches or in three years is generally 50,000 or 60,000 times, which is determined by the time between the injection of emp valve. Low pressure long bag off-line pulse dust remover three inches of electromagnetic pulse valve, generally use alternating spray, each electromagnetic pulse valve at an interval of 30 minutes, is a normal spray frequency. Three years of spraying 3×365×24×2 = 52,560 times, that is, more than 50,000 times.

 

Therefore, the service life of electromagnetic pulse valve is an important parameter, but far less mysterious than some electromagnetic pulse valve manufacturers propaganda. Because of this, electromagnetic pulse valve in the use of the spray effect, sealing and stability is the key to measure the quality of electromagnetic pulse valve.

 

 

If you have the present or future demand of our products,pls contact us without any hesitation

 

 

 

Hot Products

15mm Wire Lead Type DC24V/12V Refrigeration Coil AC220V Chiller Electric Valve Solenoid Coil The ...
1 Inch TURBO Type Black Nitrile Rubber Diaphragm for Pulse Blowing Valve The diaphragm repair kits ...
Pneumatic Power 1 1/2'' TURBO Type Pulse Valve Diaphragm M40 TURBO electromagnetic pulse valve ...
ASCO Type Green Color Pulse Solenoid Valve Coils 14mm Inside Hole Height 39.3mm Most of the coils ...
35.5mm Height 11mm Hole MSV Series Refrigeration Solenoid Valve Coils For Automatic Refrigerant ...
Pneumatic Power TURBO Type Solenoid Valve Diaphragm M55 For Pulse Blowing Valve Solenoid and ...