EVR10-012S Brass Refrigeration Solenoid Valve Control Refrigerant Flow

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

EVR10-012S Brass Refrigeration Solenoid Valve Control Refrigerant Flow

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

EVR10-012S Brass Refrigerator Solenoid Valve Control Refrigerant Flow

 

EVR solenoid valve is one-way flow of a one-time or double open solenoid valve, can be configured with a variety of voltage coil, valve body versatility.

 

Features:

  • Clamping type solenoid valve does not need to install any tools, only a screwdriver can be removed.
  • The sealing coil has a long service life and can be used in harsh conditions.
  • 10W high-power electromagnetic coil, MOPD up to 2.5mpa
  • Multiple power solenoids are available

 

Technical data:

Model:Pipe sizesH1H2H4LL2

KV value

(m³/h)

SAE

Inlet/Outlet

ODF

Inlet/Outlet

InchmmInchmmInchmmInchmmInchmmInchmm
EVR3-014EVR3-014S1/460.5142.871  4.01020.370.27
EVR3-038EVR3-038S3/8100.5142.973  4.61170.410
EVR6-038EVR6-038S3/8100.5143.179  4.41110.4100.8
EVR6-012EVR6-012S1/212.80.5143.179  5.01270.410
EVR10-012EVR10-012S1/212.80.6163.179  5.01270.4101.9
EVR10-058EVR10-058S5/8160.6163.179  6.31600.512
 EVR15-058S5/8160.7193.486  6.91760.5122.6
 EVR15-078S7/8220.7193.486  6.91760.717
 EVR20-078S7/8220.8203.590  7.51910.7175
 EVR20-118S1 1/828.80.8203.590  8.42140.822
 EVR22-138S1 3/8350.8203.590  11.12811256
 EVR25-118S1 1/828.81.5385.41382.87210.02560.82210
 EVR25-138S1 3/8351.5385.41382.87211.0281125
 EVR32-138S1 3/8351.9474.41112.15311.028112516
 EVR32-158S1 5/8421.9474.41112.15311.02811.129
 EVR40-158S1 5/8421.9474.41112.15311.02811.12925
 EVR40-218S2 1/8541.9474.41112.15311.02811.334

 

Main dimension of EVR10-012S Brass Refrigerator Solenoid Valve:

 

Packing of EVR10-012S Brass Refrigerator Solenoid Valve:

 

EVR10-012S Brass Solenoid Valve application refrigeration equipment:

 

Working principle of chiller with EVR10-012S Brass Refrigeration Solenoid Valve:
Compression is produced by the engagement of an active rotor and two star wheels. Suction, pressure and row three consecutive processes are achieved through the periodic volume change caused by the rotation of the rotor and the star wheel, the number of teeth of the rotor is 6, and the number of teeth of the star wheel is 11. The main components are rotor, double star wheel, body, main bearing and energy regulating device. The capacity can be adjusted from 10% stepless to 100%, and can be divided into three or four sections.
Principle of compression:
1,Inlet technology: the gas enters the rotor slot through the inlet. When the rotor rotates, the star wheel enters into a state of engagement with the rotor groove, and the gas enters into the compression chamber (the closed space formed by the rotor tooth surface, the casing cavity and the side of the star tooth).


2,compression process: as the rotor rotates, the volume of the compression chamber decreases continuously and the gas is compressed until the leading edge of the compression chamber turns to the exhaust port.


3,Exhaust process: after turning the front end of the compression chamber to the exhaust port, start the exhaust and complete the working cycle. Due to the symmetrical arrangement of the star wheels, each revolution is compressed twice, and the displacement is correspondingly twice the amount of the weekly cycle.

 

Selection should be made according to different operating environment, space, required cooling capacity of units and different rural areas.

Water-cooled chillers must be provided with cooling towers. The open cooling circulating water system, due to the heat absorbed by the cooling water and air contact, carbon dioxide will be released into the air, the dissolved oxygen and turbidity in the water will increase, leading to a big problem in the cooling circulating water system: corrosion, scaling, bacterial growth and sludge. If the water quality is not treated well, the refrigeration equipment will be seriously damaged, the heat exchange efficiency will be greatly reduced, resulting in energy waste.

 

Therefore, it is very important to treat the system water with corrosion inhibition, scale inhibition, sterilization and algae removal. Chiller cooling system must be equipped with electronic water treatment equipment or ferromagnetic water treatment equipment. Otherwise, the heat dissipation efficiency is too large, the use time is long. Over time, the less effective the system, the higher the annual cost of water treatment and the less likely it is to achieve 100% descaling. Cooling circulating water quality is key. The treatment of cooling circulating water is divided into physical treatment and chemical treatment. The physical methods are mainly electrostatic water treatment instrument, electronic water processor and internal magnetic water processor.

 

Welcome to your inquiry!

Hot Products

Danfoss Type EVR 32 NC Refrigeration Solenoid Valve 1 3/8'' 1 5/8'' Solenoid valves play an ...
EVR10-012S Brass Refrigerator Solenoid Valve Control Refrigerant Flow EVR solenoid valve is one-way ...
1 Inch Thread Pulse Valve CA25DD Aluminum Solenoid Valve with NBR Diaphragm The CA25DD pulse valve ...
3/4 Inch ASCO type 0.4-0.6MPa Right Angle Solenoid Dust Pulse Valve SCG353A043 Made of Aluminum SS30 ...
279834 Dryer Gas Valve Ignition Solenoid Coil Kit For Whirlpool Maytag 1. Model Number: 279834 Dryer ...
Black Color 1 Inch ASCO Type Solenoid Valve SCG353A043 for Industrial Equipment The solenoid valve ...