Operating Range | Minimum | 0.05 m/s | 0.15 ft/s | |
Maximum | pipes to DN1200 (48 in.) | 10 m/s | 33 ft/s | |
pipes over DN1200 (48 in.) | 3 m/s | 10 ft/s | ||
Pipe Size Range | DN50 to DN2550 | 2 in. to 102 in. | ||
Linearity | ± 1% reading plus 0.1% of full scale | |||
Repeatability | ±0.5% of reading @ 25 °C | |||
Accuracy | ±2% of measured value* |
*In reference conditions where the fluid is water at ambient temperature, the sensor is inserted at the correct depth and there is a fully developed flow profile which is in compliance with ISO 7145-1982 (BS 1042 section 2.2)
Minimum Conductivity | 20 μs/cm |
Wetted Materials | |
Body and Electrodes | 316L stainless steel |
Insulator | PVDF |
O-rings | FPM |
Cable | 4-cond + shield, PVC jacket (Fixed cable models) or Water-resistant rubber cable assembly with Turck® NEMA 6P connector |
Power Requirements | |
4 to 20 mA | 24 VDC ±10%, regulated, 22.1 mA maximum |
Frequency | 5 to 24 VDC ±10%, regulated, 15 mA maximum |
Digital (S3L) | 5 to 6.5 VDC 15 mA maximum |
Reverse Polarity and Short Circuit Protected
Cable Options | ||
Fixed cable | 7.6 m | 25 ft |
Detachable water tight sensor cable with Turck® connector (sold separately) two lengths: 4 m (13 ft) or 6 m (19.5 ft)
Electrical | |||
Current Output (4 to 20 mA) | Programmable and Reversible | ||
Loop Accuracy | 32 μA max. error (@ 25 °C @ 24 VDC) | ||
Temperature Drift | ±1 μA per °C max. | ||
Power Supply Rejection | ±1 μA per V | ||
Isolation | Low voltage < 48 VAC/DC from electrodes and auxiliary power | ||
Maximum Cable | 300 m | 1000 ft | |
Max. Loop Resistance | 300 Ω | ||
Error Condition | 22.1 mA | ||
Frequency Output | Compatible with | Signet 8550, 8900, 9900 and 9900-1BC | |
Max. Pull-up Voltage | 30 VDC | ||
Short Circuit Protected | ≤30 V @ 0 Ω pull-up for one hour | ||
Reverse Polarity Protected | to -40 V for 1 hour | ||
Overvoltage Protected to +40 V for 1 hour | |||
Max. Current Sink | 50 mA, current limited | ||
Maximum Cable | 300 m | 1,000 ft | |
Digital (S3L) Output | Compatible with | Signet 8900 and 9900 | |
Serial ASCII, TTL level 9600 bps | |||
Maximum Cable | Application dependent (See 8900 or 9900 manual) in non-icing conditions | ||
Operating Temp. | Ambient (non-icing conditions) | -15 °C to 70 °C | 5 °F to 158 °F |
Media | -15 °C to 85 °C | 5 °F to 185 °F | |
Max. Operating Pressure | 20.7 bar @ 25 °C | 300 psi @ 77 °F | |
Hot-TapInstallation Requirements | |||
Maximum Installation Pressure | 20.7 bar | 300 psi | |
Maximum Installation Temp (Insertion/Removal) | 40 °C | 104 °F |
Do not use hot-tap installation where temperatures will exceed 40 °C or if hazardous liquids are present.
Shipping Weights | |||
3-2552-2X-A-11/A-12 | 2.50 kg | 5.51 lb | |
3-2552-2X-B-11/B-12 | 2.30 kg | 5.07 lb | |
3-2552-3X-A-11/B-11/A-12/B-12 | 4.00 kg | 8.81 lb | |
Standards and Approvals | |||
CE, FCC | |||
RoHS compliant, China RoHS | |||
NEMA 4 (IP65) | Fixed cable models | ||
NEMA 6P (IP68) | Submersible cable models only. Signet recommends maximum 3 m 10 ft) submersion depth for maximum 10 days continuous submersion. | ||
Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety |