Urology Plasma Surgery System for BPH Treatment

Country/Region china
City & Province chengdu sichuan
Categories Other Beauty Equipment
InquireNow

Product Details

Urology Plasma Surgery System for BPH Treatment

 

 

Product Introduction

 

This PLA-600 Model Urology Plasma Surgery System are designed to appliy into the field of urology. On the front panel, there are two working modes, Ablation mode and Coagulation mode. Which can be adjust from 1 to 10 level by push the plus + or reduce - button. It is widely applying to BPH and Bladder tumor treatment.

 

Product Diagram

 

 

 

Technical Parameter

 

Input Volts

198-240V 50Hz

100-120V 60Hz

Export device could convert automatically per customer requirements

Output Power

Ablation or resection: ≤351W

Coagulation or hemostasis: ≤111W

Working Frequency100 KHz ± 10%
Dimension405*440*130mm (L*W*H)
Working Mode

Ablation and resection: level 1-10

Coagulation: level 1-10

Weight7.0kg

 

Product Advanatages

 

  • Safety: multi-polar design, change the traditional way that current flow through human body
  • Low Temperature: 40 to 70 centigrade during operation, decrease the thermal damage to around normal tissue
  • Precise cutting: the thin plasma layer make precise cutting becoming true, and it will not hurt the around normal tissue
  • Speedy cutting: cutting and coagulation at the same time, no need to change the probe frequently, saving operation time
  • Shorten recovery period: less hurt to human body, recovery faster

 

System Set Up

 

DescriptionRemark
Manufacturer LogoMECHEN Brand.
PadsInsulation and support on the surface.
Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment HandleConnects with the treatment accessories.
Power SwitchSystem start power button. “O” means power off; “I” means power on.
ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

 

System Component

 

1). One tabletop generator device

2). One reusable and non-sterile power supply cable.

3). One reusable and non-sterile footswitch.

4). One reusable and non-sterile treatment handle which is for foot control.

5). Treatment probes.

 

 

Storage Condition

 

This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:

1. Temperature: -40℃~+55℃;

2. Relative humidity: ≤90%;

3. Atmospheric pressure: 50kPa~106kPa

Hot Products

ENT Plasma Surgery System for Tonsillectomy and Adenoidectomy ENT Plasma Surgery System Product ...
Urology Plasma Surgery System for BPH Treatment Product Introduction This PLA-600 Model Urology ...
Orthopedic Plasma Surgery System for Spine and Joints Treatment Product Introduction This PLA-800 ...
Fast Healing Plasma Wand Tonsillectomy RF Ablation System Plasma Surgery System Indications: Adenoid ...
PLA201 Gynecology Plasma Probe Used for Repair Scars of the Uterus 1. Operation Guidance When the ...
Mechan Plasma ENT Probe for Tubinate Channeling and Ablation Operation Guidance When the cable plug ...