Analog PH / ORP Controller With Historical Data Records And RS485 For Sewage Or Drinking Water

Country/Region china
City & Province suzhou
Categories Electrical Instruments
InquireNow

Product Details

 

Analog PH/ ORP Controller With Historical data records and RS485 For Sewage Or Drinking Water

 

pH controller APX2-C3 with historical record functionality and an RS485 communication interface offers the following features and advantages:

Historical Record Functionality:

Data Logging: The pH controller can record past pH value data, typically with timestamps, allowing users to review and analyze pH trends and variations over a certain period.

Event Logging: In addition to pH values, the pH controller can also log events related to the control process, such as alarm events, calibration events, operational records, etc., facilitating troubleshooting and quality control.

Historical Data Storage: pH controllers typically provide options for internal or external data storage, enabling long-term retention of historical data for future analysis and review.

RS485 Communication Interface:

Real-time Monitoring and Control: Through the RS485 communication interface, the pH controller can transmit real-time pH data to monitoring systems, computers, or other devices, enabling real-time process monitoring and control.

Data Transmission Security: RS485 communication boasts high noise immunity, ensuring the reliability and security of data transmission, particularly suitable for long-distance data transfer in industrial environments.

Integration: pH controllers can be integrated with other devices such as PLCs, data acquisition systems, etc., making the entire automation control system more coordinated and efficient.

In summary, a pH controller with historical record functionality and an RS485 communication interface provides comprehensive data recording and monitoring capabilities, while also supporting flexible control and access. It is well-suited for applications in industrial processes and laboratory settings that require high levels of automation and precise control.

 

Specification:

 

ModelAPX2-C3 APX2-G4
PrinciplePHGlass pH electrode (hydrogen ion concentration index)
ORPPlatinum or gold electrodes (redox potential)
Display RangePH0~14pH
ORP± 2000mV
Temp-10~150℃
Solution GroundN/A Differential ground
ResolutionpH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability0.05% of measuring range every 24 hours without accumulation
RepeatabilityBetter than 0.1% of measuring range
Temp CompensationAutomatic or manual (NTC10K/PT1000)

 Automatic or manual (NTC10K/PT1000)

 Converted at 25°C

Relay OutputTwo SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or clean control
Digital CommunicationA two-wire RS485, Modbus, JSON
Current OutputTwo 0/4~20mA current Max. load 1000Ω
LanguageEnglish English and Chinese
Time DisplayYear/month/date hour/minute/second
Historical Data

10000 historical data can be recorded,

Record the last 100 calibration maintenance data

Display128*64 3.2-inch graphic dot matrix LCD
Calibration MethodPH: 3 points; ORP: 2 points

 PH: 3 points; ORP: 2 points

 PH: 5 points multi-slope calibration

Protection GradeIP66
Enclosure MaterialEnhanced ABS
Power SupplyAC: 100~240V or DC:18~36V, 50/60Hz
Dimension144*144*120mm (Hole size 138*138mm)
Electrical InterfaceReserve three M12*1.5 glan heads, the wire diameter is 3~6.5mm
Work Temperature0~60℃, RH<95%, non-condensing
Storage Temperature-20~70℃, RH<55%, non-condensing
InstallationWall mounting, pipe clamp, panel
Power ConsumptionMax. 3W

 

 

Brief introduction:

  • 3.2 inch LCD screen
  • Time and historical data can be recorded
  • Temperature compensation function
  • 6 Password can be set
  • 144*144*120mm dimension
  • English interface
  • Calibration points are adjust freely

The use environment includes but not limited to the following:

Laboratory environment:
pH and ORP sensors are commonly used in laboratories for chemical analysis, biological experiments and research applications. These environments are often tightly controlled to ensure high precision and accuracy.
Industrial production:
Chemical plants, pharmaceutical plants, food processing plants, and other industrial sites use pH and ORP sensors to monitor and control production processes. This helps ensure product quality, increase production efficiency and avoid unnecessary waste.
Environmental monitoring:
pH and ORP sensors are widely used in the field of environmental monitoring to detect and monitor the properties of water, soil, wastewater and pollutants. This helps protect the natural environment and human health.
Water treatment:
Drinking water treatment plants and wastewater treatment plants use pH and ORP sensors to monitor and regulate the pH and redox properties of water to ensure water quality is up to standard.
Pool and Spa:
pH sensors are used to monitor the pH level of swimming pool and spa water to maintain clean and safe water.
Agriculture:
The field of agriculture uses pH sensors to monitor the pH of the soil to determine the most suitable soil conditions for growing different crops.
Food and drinks:
The food and beverage processing industry uses pH sensors to monitor and regulate the pH of food products to ensure product safety and taste.
Aquarium:
pH and ORP sensors are used to monitor the quality of water in fish tanks, aquariums and aquarium exhibits to ensure the health of fish and aquatic life.
It should be noted that different applications may have different requirements for sensor accuracy, durability and environmental conditions. Therefore, when choosing pH and ORP sensors, you must consider the characteristics of the use environment and choose a suitable sensor model to ensure accurate and reliable measurement.

 

 

 

Hot Products

5 Points Multi-Slope Calibration And Differential Signal Solution Ground Analog PH/ ORP Controller ...
Analog PH/ ORP Controller With Historical data records and RS485 For Sewage Or Drinking Water pH ...
Analog PH/ ORP Controller With RS485 Two Relays Control Dosing For Sewage Or Drinking Water The pH ...
Online PH/ ORP Controller With Two Relays Control Dosing For Water Treatment Plant pH controllers ...
Online PH/ ORP Transmitter with RS485 Two Relays two 0/4~20mA Output For Sewage Or Drinking Water ...
Online PH/ ORP Controller With Differential Signaling Solution Grounding 5-Point Calibration For ...