Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

One 0/4 - 20mA Current Output Online PH / ORP Controller For Sewage Or Drinking Water

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

One 0/4 - 20mA Current Output Online PH / ORP Controller For Sewage Or Drinking Water

Country/Region china
City & Province suzhou
Categories Measuring & Analysing Instrument Design Services
InquireNow

Product Details

 

Two Relays One 0/4~20mA Current Output Online PH/ ORP Controller For Sewage Or Drinking Water

 

Analog pH and ORP (Oxidation-Reduction Potential) controllers APX1-C1 are devices used to maintain and regulate the pH and redox properties of liquids. Use with pH and ORP sensors for precise control and monitoring.

 

Specification:

ModelAPX1-C1APX1-C1Z
PrinciplePHGlass pH electrode (hydrogen ion concentration index)
ORPPlatinum or gold electrodes (redox potential)
Display RangePH0~14pH
ORP± 2000mV
Temp-10~150℃
ResolutionPH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability0.05% of measuring range every 24 hours without accumulation
RepeatabilityBetter than 0.1% of measuring range
Temp CompensationAutomatic or manual (NTC10K/PT1000)
Relay OutputTwo SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or clean control
Digital Communication——A two-wire RS485 interface, Modbus RTU
Current OutputA 0/4~20mA current Max. load 1000Ω
LanguageEnglish
Display128*64 3.2-inch graphic dot matrix LCD
Calibration MethodPH: 3 points ORP: 2 points
Protection GradeIP66
Enclosure MaterialEnhanced ABS
Power SupplyAC: 100~240V 50/60Hz or DC:18~36V,
Dimension100*100*120mm (Hole size 92*92mm)
Electrical InterfaceReserve three M12*1.5 glan heads, the wire diameter is 3~6.5mm
Work Temperature0~60℃, RH<95%, non-condensing
Storage Temperature-20~70℃, RH<55%, non-condensing
InstallationPanel
Weight450g
Power ConsumptionMax. 3W

 

 

Brief introduction:

 

  • 3.2 inch LCD screen
  • Password can be set
  • Quick calibration button
  • Calibration points can be set freely
  • Power failure protection, indefinite retention of parameters
  • Two SPST relays to set high and low alarms and control dosing

  • A 0/4~20mA current Max. load 1000Ω

The use environment includes but not limited to the following:

Laboratory environment:
pH and ORP sensors are commonly used in laboratories for chemical analysis, biological experiments and research applications. These environments are often tightly controlled to ensure high precision and accuracy.
Industrial production:
Chemical plants, pharmaceutical plants, food processing plants, and other industrial sites use pH and ORP sensors to monitor and control production processes. This helps ensure product quality, increase production efficiency and avoid unnecessary waste.
Environmental monitoring:
pH and ORP sensors are widely used in the field of environmental monitoring to detect and monitor the properties of water, soil, wastewater and pollutants. This helps protect the natural environment and human health.
Water treatment:
Drinking water treatment plants and wastewater treatment plants use pH and ORP sensors to monitor and regulate the pH and redox properties of water to ensure water quality is up to standard.
Pool and Spa:
pH sensors are used to monitor the pH level of swimming pool and spa water to maintain clean and safe water.
Agriculture:
The field of agriculture uses pH sensors to monitor the pH of the soil to determine the most suitable soil conditions for growing different crops.
Food and drinks:
The food and beverage processing industry uses pH sensors to monitor and regulate the pH of food products to ensure product safety and taste.
Aquarium:
pH and ORP sensors are used to monitor the quality of water in fish tanks, aquariums and aquarium exhibits to ensure the health of fish and aquatic life.
It should be noted that different applications may have different requirements for sensor accuracy, durability and environmental conditions. Therefore, when choosing pH and ORP sensors, you must consider the characteristics of the use environment and choose a suitable sensor model to ensure accurate and reliable measurement.

 

 

 

Hot Products

5 Points Multi-Slope Calibration And Differential Signal Solution Ground Analog PH/ ORP Controller ...
Analog PH/ ORP Controller With Historical data records and RS485 For Sewage Or Drinking Water pH ...
Analog PH/ ORP Controller With RS485 Two Relays Control Dosing For Sewage Or Drinking Water The pH ...
Online PH/ ORP Controller With Two Relays Control Dosing For Water Treatment Plant pH controllers ...
Online PH/ ORP Transmitter with RS485 Two Relays two 0/4~20mA Output For Sewage Or Drinking Water ...
Online PH/ ORP Controller With Differential Signaling Solution Grounding 5-Point Calibration For ...