Product Details

 

COVIDIEN Nellcorrr Pulse Oximetry Patient Interface Cable 10Ft 3.0m REF DOC10 OxiMax pulse Sensor Extension Cables

 

 

► Brief Introduction

COVIDIEN Nellcorrr Pulse Oximetry Interface Cable DOC-10 is an assembly consisting of the parts of the SpO2 sensor.

Connect the cables prior to attaching to the monitor. An SpO2 reading will be displayed within moments of attaching the sensor to either a Nellcorrr simulator or to your finger.

It’s work for GE Carescape B650, GE Carescape V100, GE E-NSAT, GE Pro 1000, GE Pro 1000 V3, GE Pro 200, GE Pro 300, GE Pro Series V2, GE ProCare, GE ProCare 100, GE ProCare 200, GE ProCare 300, GE ProCare 400, GE ProCare Ausculatory 400

The SpO2 probe has a built-in sensor. When the SpO2 sensor is connected to the SpO2 connector and the patient, the probe senses heart rate and oxygen saturation. Analog signals are directed to SpO2 PWA (Nellcorrr or Masi-mo). Analog signals are analyzed on SpO2 PWA. Results are numbered and sent to the main panel via optics interfaces. The hooks provide patient isolation as well as a serial data interface. The main panel temporarily stores data and directs it to the user interface panel for viewing and/or printer.

 


SpO2 - Nellcorrr Pulse Oximetry

SpO2 Range and Accuracyadult/neonate: 70-100% ±3.5 digits
Pulse Rate Range and Accuracy30 - 250 BPM ±3 BPM
Saturation Pitch IndicatorPitch changes with saturation
Sensor Connect/Disconnect from PatientThe Monitor detects the connection or disconnection or a
sensor to the patient within 15 seconds
Sensor Connect/Disconnect from MonitorThe monitor detects the attachment or disconnection of a
sensor from the Monitor within 5 seconds
Pulse DetectionThe Monitor detects a pulse of enters a no-signal state
within 15 seconds of being attached to a patient
Loss of Pulsethe monitor detects loss of pulse from patient and enters a
no signal state within 10 seconds

 

 

Cleaning

 

Clean the surface of the SpO2 sensor before and after each patient is used. Clean the SpO2 sensor with a slightly wet cloth with a mild cleaner. Wipe the SpO2 sensor to ensure that all detergent residues are removed.

 

Caution: Don't put isoprop alcohol on the screen - some parts may crack and crack.

 

Compatible cleaning and sterilization solutions are:

  1. Chlorinated disinfectant, 5.25%, 0.75 cups per gallon of water.
  2. Cidex Formula 7 (registered trademark of Johnson & Johnson Medical Products, Inc.) or PhilipilipisoHex (registered trademark of Winthrop-Breon Laboratories.)
  3. Quad-microbicide detergents such as VESTAL INSURANCE (registered trademark of Vestal Corp.), HI-TOR PLUS (registered trademark of Huntington Corp.) or VIREX (registered trademark of S.C. Johnson & Son Corp.)

For the above, follow the manufacturers' recommendations for mitigation and use rate. These recommendations are not authenticated by manufacturers or on the effectiveness of these materials in cleaning or disinfection.

 

 

 

Please kindly contact us, if you are interested in COVIDIEN Nellcorrr Pulse Oximetry Patient Interface Cable 10Ft 3.0m REF DOC10 OxiMax pulse Sensor Extension Cables, Thank you!

 

Hot Products

Hospital Medical Equipment Stryker Endoscopy X-6000 X6000 Xenon Light Source, 220-185-000 ►Brief ...
Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale GE Dash2000 device is designed ...
Hospital Medical Equipment Mindray BeneHeart R12 ElectrocardiograPhilipilip ECG Machine ► Brief ...
004-0004-004 2016792-002 REV A GE Dash4000 patient monitor display assembly 10.4inch Display ...
2026653-019 GE Dash3000 Dash4000 Dash5000 Patient Monitor Battery Door Battery door features High ...
P/N 2019271-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Display Flex Flat Cable About company ...