L14-6we Mindray Linear Array Probe For DC-8 Ultrasound Machine

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

L14-6we Mindray Linear Array Probe for DC-8 Ultrasound machine

 

 

 

 

As a high-density transducer, Mindray’s L14-6we linear array ultrasound transducer can generate multiple types of ultrasound images. These options include blood vessels, small parts, musculoskeletal, neurological, and pediatrics. With 6-14 MHz. Frequency range, the probe is compatible with Mindray DC-70 and DC-8 ultrasound systems

 

Form FactorLinear Array
ApplicationsSmall Parts, Vascular, Musculoskeletal, Pediatrics
Frequency Range6.0 - 14.0 MHz
CompatibilityMindray DC-8; Mindray DC-70
Imaging ModesNot yet available
FeaturesNot yet available
Cable Length1950±50mm
Bandwidth5.1 – 12.5MHz(-6dB); 3.5 – 16MHz(-20dB)
Number of Elements256
Field of View (max)50mm
Steered Angle+/-6°,12°(B); +/-10°, 20° (C, PW)
B-mode Frequencies4.8 – 10.6, 5.4 – 11.6, 6.6 – 13.5MHz
Harmonic Frequencies8.0, 10.0, 12.0MHz
Doppler Frequencies5.0, 5.7, 6.6MHz
Biopsy GuideAvailable, multi angle, reusable

 

 

 

Before performing intracavitary and intraoperative inspections, a legally sold probe sheath must be installed on the probe. A protective barrier may be needed to minimize the spread of disease. The probe sheath can be used in all clinical situations where infection needs to be considered

1. Put an appropriate amount of gel in the sheath or on the acoustic lens of the probe. If the gel is not used, it may cause poor imaging.

2.Insert the probe into the sheath; make sure to use proper aseptic technique. Pull the cover tightly on the acoustic lens of the probe to remove wrinkles and bubbles, and take care to avoid piercing the sheath.

 

3.Fix the sheath with the attached elastic band.

 

4. Inspect the sheath to make sure there are no holes or tears.

 

 

ModelLength(mm)Width(mm)Height(mm)Cable Length(mm)
C5-2E11276261950±50
V11-3E31741221950±50
D6-2E1247151.62260±50
P4-2E10038301950±50
L14-6WE10270251950±50
L14-6NE10261241950±50
L12-3E10261241950±50
C7-3E11071231950±50
C11-3E9433251950±50
DE10-3E29452432260±50
V11-3BE31964211950±50
V11-3WE31825211950±50
L7-3E10261241950±50
CB10-4E32422202260±50
P7-3E7934251950±50
P10-4E8329201950±50
P4-2NE10280181950±50
CW2s12080182100±50
CW5s12311112050±50

 

 

Hot Products

3D4-8ET Samsung Medison Ultrasound Probe for Accuvix V20. Accuvix V10. SonoAce R7 Live 3D. SonoAce ...
Mindray IMEC7 Patient Monitor With ECG, RESP, NIBP, SpO2, PR, TEMP Parameters Mindray iMEC 7 patient ...
Hospital Medical Equipment Used Patient Monitor Edan SE-2003 SE-2012 Holter System ► Brief ...
Hospital Medical Equipment Stryker Endoscopy X-6000 X6000 Xenon Light Source, 220-185-000 ►Brief ...
Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale GE Dash2000 device is designed ...
Hospital Medical Equipment Mindray BeneHeart R12 ElectrocardiograPhilipilip ECG Machine ► Brief ...